HQ Series Quarter-turn Electric Actuator
Installation Operation& Maintenance Manual
Doc No. : HumG-HQ-21 Rev2 Page 11 / 26 Valve Automation Leader, HKC
Anti-vibration type General type
4.8.2. Calibration of Zero and Span – CPT
The settings of Zero and Span have been
calibrated at the factory. However, if re-
calibration is required, proceed as follows:
Apply power (or use the manual override) to
drive the actuator to its fully closed position
(clockwise rotation).
When the actuator is in the fully closed
position, adjust the ZERO dial on the CPT
board until a reading of 4mA is achieved.
Apply power (or use the manual override) to
drive the actuator to its fully open position
(counter-clockwise rotation).
When the actuator is in the fully open
position, adjust the SPAN dial on the CPT
board until a reading of 20mA is achieved.
4.9. Proportional Control Unit
[Never welding should be done while the power line is connected to the actuator. Electrical shock
can cause serious damage to the microprocessor of the actuator. ----- 17 Rev1]
4.9.1. [PCU EB-V1.5D for AC, Optional
Front Back
4.9.2. [PCU DC-V2.1C for DC, Optional
Front Back