Holtkamp Electronics UNO 7600XL engl. techn. Stand 04.2016 4050_04.2016 V09.2019
- 29 -
17.9 Remote indications incl. connection possi-
bi-
lity in UNO with or without remote start
TheremoteindicationisanadditionaldevicewithLEDdisplay,
whichshowstheclienttheremainedtime,locallypartedfromthe
UNO.Theremoteindicationiswithorwithoutremotestartbut-
ton.IfyourUNOhasbeenorderedwitharemotestartbuttonyou
canndontheSBframe,ontheinsideofthebackofthedevice,
anadditionalcircuitboard,whichneedstobeconnectedtothe
remoteindicationasfollowing:
Theneededconnectioncableisnotincludedbydelivery.
Connection to the XL with 4-pol. installation cable (shielded,
screenononesidepresented)maximumconduitlength12m.
PCB Remote indication
Component side
XLData
connection
Switch
connection
potential free
relay contact
Connections:
GND - GND(-)
TxD - TxD(T)
RxD - RxD (R)
+UB - +UB(+)