EasyManua.ls Logo

Holtkamp UNO Series - 8 Installation; Installation Notes; Mounting Notes; Mounting Instructions

Holtkamp UNO Series
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Holtkamp Electronics UNO 7600XL engl. techn. Stand 04.2016 4050_04.2016 V09.2019
- 9 -
8 Installation
8.1 Installation notes
Throughhighqualitymicro-electronicsisthedevice abletore-
ach a high standard of reliability in the daily use. Only if the in-
stallation has been professionally carried out can the device be
guaranteed.
Pleaseconsiderduringtheinstallation,...
Onlyauthorizedandqualiedelectricianscarryoutthein-
stallationcomplyingwiththevalidVDE–regulations.
Bythetimerswith230V~supplyvoltageisdenitelythe
protectioncablerequired,bythetimers24V~(safetyex-
tra-low voltage) protecting grounding is needed as function
earth.
Thattheoorcoveringisanti-staticandconductorcapable,
toensureaminimumofstaticchangeandsoreducingthe
danger to the electronics.
Amalfunctionorbreakdownofthedevicecanbecaused
bytheswitchingsparksoftherelaycontacts.Toreducethese
sparksappropriatesuppressioncombinationsmustbein-
cludedparalleltotheprotectioncontacts.RCcombinations
forsparksreducingareonlya󰀨ectivebydirectparallelswit-
ching of the relay contacts.
Thatthescreenedcontrolanddatacablearelaidsepara-
telyfrommainscables.ThescreeningoftheUNOelectro-
nicmustbeone-sideandlaidonPE
Thatthefeedlineareused,whichisfromabigcrosssecti-
ontosupplyboththeUNOandtheattachedelectricconsu-
mer.Itshouldbeusedancrosssectionfrom1,5mm²atthe
minimum
8.2 Mounting notes
Thisdevicemayonlybemountedonasuitablesurface.
Thedevicemustbesu󰀩cientlysecured,takeintoconsi-
derationtheweightoftheinsertedcoins.Thereare6holes
inthebackofthecasingtoaccomplishthemountingpro-
cess.Screwsanddowelsareincludedbydelivery.
Thedevicemustbemountedhorizontallyandverticallyto
guarantee a awless function of the coin receiver.
Thatmeanstheangleofthedevicecanonlybemaximum
2°,slopingforwardorbackward,aswellastotherightor
the left.
Thedevicemustbemountedperpendicularandhorizontal-
ly,toavouchafaultlessfunctionofthecoinacceptance.
Thatimplies,thetiltangleofthedevicecanonlybemaxi-
mal2°forwardsorbackwardsandmaximal2°totherightor
left.
Theinputcablesarexedbythreedrilledholesintherear-
wall.ThedeviceiscorrespondingtoprotectiontypeIP20
andmayonlybeusedindryrooms.Chooseacablecross
section of the feed line adequate big. Attend thereby the
connected electrical load. Attend to the VDE guidelines.
8.3 Mounting instructions
Shutdownthepowerinput,byactivatingtheimmobilising
switch,thefuseoreventhemainsafetyfuse.
Unlockandremovethecoinbox
Loosenthetwoscrewsofthefuseplate,removethefuse
plate and raise the casing so that it is possible to pull out the
electrical connectors. Pull out the electrical plug connec-
tionsandremovethecasingcompletely.
Thewallplatehorizontalandverticallyalignwiththehelp
of a level.
The tilt angle can only be 2° now mark the drilled holes.
Drilltheholesandinsertsuitabledowels.Throughtheholes
“15”(seeimage1.1ofthedevice)ontherearwallconnect
up the electricity. With the appropriate screws secure the
casing tightly. Now reinstall the electrical connections.
Placethecasingonthexingbolts“14”.Asacountermea-
sureplacethefuseplate,throughtheopeningoftheremo-
vedcoinbox,onthexingbolts“13”andtightenwiththe
supplied screws.