Malfunction Possible causes Possible remedy
Thevalueofthecountersarenotcorrect wrong channel values adjusted correct the channel values
ThedisplayshowserrormessageE03or
E04
EEPROMmemoryisdefect sendUNOtorepairation
ThedisplayshowserrormessageE12
Maximum time is adjusted smaller than
themaintime
Adjust the maximum time or change the
maintime
ThedisplayshowserrormessageE17 DIPswitchno.3ison“OFF” setDIPswitchno.3on“ON”
ThedisplayshowserrormessageE18or
E19
EEPROMmemoryisdefect sendUNOtorepairation
ThedisplayshowserrormessageE20 DIPswitchno.2ison„on“ setDIPswitchno.2on„o󰀨“
ThedisplayshowserrormessageE27
By FairPlay: the two FairPlay steps and
the 3. service interval must be program-
medinascendingorder
FairPlay step 1 must be smaller or even
step2,step2mustbesmallerorevenwith
the service interval 3
ThedisplayshowserrormessageE32
Bybonusoperation:Nodiscountcouldbe
assigned, because programming contra-
dictsthebonussystem
The programmed prices and main times
must be so adjusted, that with reaching
a bonus step no negative bonus is assi-
gned,customerlosttimeinsteadgetmore
ThedisplayshowserrormessageE33 Bybonusoperation:Falseprogramming!
The programmed prices and main times
mustbeprogrammedinascendingorder.
Example: Time 1 must be smaller than
time2,time2mustbesmallerthantime3.
Thepricessimilar.