EasyManua.ls Logo

Holux GR-213 - Manufacturing Default; Datum Change Syntax

Holux GR-213
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HOLUX
13
43 Latvia – S-42 (Pulkovo 1942) Krassovsky 1940 Data67.dat
44 Liberia – 1964 Clarke 1880 Data36.dat
45 Mexico, central America GRS1980 Data38.dat
46 OMAN Clarke 1880 Data39.dat
47 Pakistan Everest 1830 Data40.dat
48 Paraguay - South American 1969 South American 1969 Data42.dat
49 Peru1 – South American 1969 South American 1969 Data41.dat
50 Philippines Clarke 1866 Data43.dat
51 Poland – S-42 (Pulkovo 1942) Krassovsky 1940 Data68.dat
52 Potsdam Bessel 1841 Data71.dat
53 Puerto Rico – Virgin Islands Clarke 1866 Data44.dat
54 Qatar national International Data45.dat
55 Qornoq – Greenland (SOUTH) International Data46.dat
56 Regional Mean South American 1969 Data48.dat
57 Reunion – Mascarene Islands International Data47.dat
58 Romania – S-42 (Pulkovo 1942) Krassovsky 1940 Data69.dat
59 Rome 1940 – Italy International Data49.dat
60 Saudi Arabia – Ain el Abd 1970 International Data50.dat
61 Singapore Modified Fischer 1960 Data51.dat
62 South Africa Clarke 1880 Data52.dat
63 Thailand 1975 Everest 1830 Data54.dat
64 Tokyo_Japan Bessel 1841 Data60.dat
65 Tokyo_Korea Bessel 1841 Data61.dat
66 Tokyo_Mean Bessel 1841 Data59.dat
67 Tokyo_Okinawa Bessel 1841 Data62.dat
68 Trinidad, Tobago South American 1969 Data55.dat
69 Venezuela South American 1969 Data57.dat
70 Venezuela – Provisional American 1956 International Data56.dat
71 WGS84 WGS84 Data58.dat
6.2 Setting Syntax
6.2.1 Manufacturing Default:
Datum: WGS84.
Baud Rate: 4800.
Output: GGA, GSA, GSV, RMC.
6.2.2 Datum change syntax:
>DOS\Sirfprog /Fdataxx.dat –Px –Bx –Csh1
-Px: x is com port, 1= COM1, 2 = COM2
-Bx: Baud rate, 4800, 9600, 19200 or 38400
Example:
Change Datum to WGS84,
Sirfprog /Fdata58.dat –P1 –B4800 –Csh1 <Entry>
After changing datum, the new datum will be kept in SRAM. If no power supplied to GR-213 for more
than 30 days, user must re-set datum when power on.