33
Start-up
Switch o the fuse of the power circuit.
Connect the switched phase conductors for con-
necting terminals 1 and 2 to the motor as follows
(see fig. 2):
- Connecting terminal 2 (C): “Up”
- Connecting terminal 1 (D): “Down”
Connect the phase conductor to connecting ter-
minal L (E) (see fig. 2).
Connect the neutral conductor to connecting
terminal N (F) (see fig. 2).
Connect an external shutter push-button to con-
necting terminal S1 and S2 (see fig. 2):
- Connecting terminal S1 (G): “Down”
- Connecting terminal S2 (H): “Up”
Connect the neutral conductor of the motor to
the neutral conductor of the house installation.
Connect the phase connection of the shutter
push-button with the phase conductor of the
house installation.
Fix the actuator to an appropriate surface-mount-
ing box (e.g. Abox 025 or Abox 040) (see fig. 3).
Fix the actuator to the holding mandrel using the
fixing lug. Screw the actuator if required.
Close the surface-mounting box using the corre-
sponding cover.
Switch the fuse of the power circuit on again, to
activate the teach-in mode of the device (see „5.3
Teaching-in“ on page 34).