Installation
5.1.3 Support ring
The valves from dierent manufacturers may have tolerance fluctua-
tions that make the radiator thermostat more loosely seated on the
valve. In this case, the provided support ring (Q) should be placed into
the flange before mounting the radiator thermostat (see figure 5).
5.2 Adaption run
Once the batteries have been inserted, the motor reserves.
Meanwhile, “InS” and the activity symbol ( ) are displayed.
After the radiator thermostat has been mounted successfully, an
adaption run (AdA) has to be performed in order to adapt the device
to the valve:
As soon as “AdA” is displayed, press the menu/boost button (G) to
start the adaption run.
It is now that the radiator thermostat performs an adapting run. “AdA”
and the activity symbol ( ) are displayed. Wait until the adaption run is
completed. Afterwards, the display returns back to normal.
If the adapter run has been initiated prior to mounting or if
an error message (F1, F2, F3) is displayed, press the menu/
boost button (G) and the motor reverses to the “InS”
position.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Homematic IP HmIP-SK9 and is the answer not in the manual?

Homematic IP HmIP-SK9 Specifications

General IconGeneral
BrandHomematic IP
ModelHmIP-SK9
CategoryControl Unit
LanguageEnglish

Related product manuals