14 AS302P Single Phase Smart Meter
____________________________________________________________________
© Honeywell - M450 001 1D - 23.05.2019
9. OPERATING MODES
The AS302P can be configured to operate in Credit or Prepayment Mode. If no parameters are sent the meter will remain
as programmed during Manufacture. The following mode switching configurations are available:
Credit to Prepayment
Prepayment to Credit
Credit to Credit
Prepayment to Prepayment
The mode of operation is available on the display and through the HAN for other devices.
9.1. Change of Operating Mode
On any change of mode the following actions occur:
A Set of Billing Data is Recorded
The Time and Date is Recorded
The Meter Balance is Set to Zero
Credit Mode to Prepayment Mode (or Credit to Credit)
As above.
Prepayment to Credit Mode (or Prepayment to Prepayment)
As above
Prepayment Billing Information is recorded
GBCS Use Case ECS03 Set ESME Payment Mode to Prepayment” is used to switch the Meter to Prepayment mode. On
using this use case the following parameters are configured in the meter:
New account in Prepayment mode
Disablement threshold
Suspend Debt Disabled and Suspend Debt Emergency
Activation time for the new account, Disablement Threshold and Suspend Debt Disabled / Emergency
parameters
GBCS Use Case ECS02 Set ESME Payment Mode to Credit is used to switch the Meter to Credit mode. On using this
use case the following parameters are configured in the meter:
New account in Credit mode
Suspend Debt Disabled and Suspend Debt Emergency Note: these are not actually used in credit mode
Activation time for the new account and Suspend Debt Disabled / Emergency parameters
10. CHANGE OF SUPPLIER AND TENANCY
The AS302P can be programmed with an Activation Time/Date for a New Supplier or a New Tenant (Restrict Data). This
will be actioned by a command from DCC.
10.1. Contact Details
Name and Phone Number for the Supplier is available on the Meter Display and can be configured as follows:
Supplier Details 15 characters
Supplier Phone Number 18 characters