12 E
3
Point Network Gas Monitor User Manual
Using the Programming Menus
Password Menu
Access to the programming menus is password protected. The Password
screen displays after enter is pressed.
Password
AA
• Press the arrow key (up or down) to change the first letter to H.
• Press the enter and use the arrow keys to change the second
letter to A.
• Press enter to confirm the password and access the menus.
• Use the arrow keys to scroll through the menu options.
• In the event of an entry error, the unit reverts to normal display
mode. Restart the login process.
Network Menu
The Network menu contains several sub-menu options: Address,
BaudRate, BACnet ID, and Protocol. Use the arrow keys to scroll to the
desired option and press enter to select:
* Menu *
Network
Address: Use the arrow keys to increase or decrease the address
value (from 001 to 254 in Modbus or 1 to 127 in BACnet)
and press enter to confirm the desired address
BaudRate: Use the arrow keys to scroll through predefined baud rates
(4800, 9600, 19200, 38400, 57600) and press enter to
select.
BACnetID: Use the arrow keys to increase the value to the desired
BACnet ID and press enter to confirm.
Protocol: Use the arrow keys to scroll to desired communication
protocol (Modbus, 201T emu, BACnet) and press enter to
confirm.