Galaxy Dimension Installer Manual
6-69
51 - Parameters (cont’d)
67 = Level Format
This parameter determines the format used for user code authorization levels.
1 = EN.Galaxy (Default)
Uses new EN Galaxy user types 1.0 to 3.8.
2 = Galaxy
Uses standard Galaxy levels 0-8.
68 = Line Fail
This parameter allows the programming of the period between the panel being alerted by a communication
module of a Line Fail condition, and the user being alerted of the alarm condition. This value can be pro-
grammed between 0 and 1800 seconds. The default is 50 seconds.
NOTE: The communication module may take up to 40 seconds to alert the panel of a Line Fail condition.
This time is in addition to the programmed time of 0-1800 seconds.
This parameter affects all communication modules on the system.
69 = Alert Inds
This parameter allows the alert audio indication to be switched off. The default is 1 = Audio only.
0 = No Indication
1 = Audio Only
2 = Visual Only (only when parameter 63 enabled)
3 = Audio/Visual (only when parameter 63 enabled)
70 = SWDC Set Dly
When enabled, this parameter delays the indication of open zones at the start of a set sequence whilst the
Switch DC output (53.08) is active; this includes keypad text and sounders.
If there are no outputs programmed as Switch DC then there will be no delay at the start of the set.
71 = MF BL Enable
When enabled, this parameter allows the panel to send a SIA event when the battery is low and there is a
mains power failure. When the event is sent, the Power Delay time set in parameter 51.20 stops immediately.
72 = Max Alm Cause
This option defines the range of valid cause codes, as agreed with the Alarm Receiving Centre. When this
function is enabled, a cause code must be entered by the user when a reset of the system is required.
This parameter can be disabled by setting the alarm cause code to 000.
73 = Guard Unset
If set to 1 = Enabled this option allows a type 2.1 user code to unset the system if an alarm has occured. The
user code becomes type 2.4 after 3 minutes of the alarm but after 60 minuts returns to type 2.1. The user
code can set the system at any time provided there are no outstanding resets required.

Table of Contents

Other manuals for Honeywell Galaxy Dimension GD-96

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension GD-96 and is the answer not in the manual?

Honeywell Galaxy Dimension GD-96 Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Dimension GD-96
CategoryControl Panel
LanguageEnglish

Related product manuals