Galaxy Dimension Installer Manual
6-176
Option 67 – Remote Reset
The Remote Reset option allows a user to perform an engineer reset authorized by the Alarm Receiving
Centre (ARC). In the event of an alarm that requires an engineer reset, the keypad displays a number, which,
when quoted to the ARC is decoded and exchanged for a new number. When this new number is entered it
resets the Galaxy panel. Entering the engineer code also resets the Galaxy panel.
NOTE: The alarm conditions that require to be reset remotely must have the appropriate System Reset,
Tamper Reset or PA Reset parameters programmed for engineer reset (type 3.7).
Each alarm activation generates a random number, therefore, the number required to reset the panel changes
each activation. As ARCs have different decoding equipment, the appropriate reset system must be selected
from the following Remote Mode options:
0 = OFF (default).
1 = SMS - Southern Monitoring Service (4 digits).
2 = Technistore (5 digits) - requires a four digit local modifier (000 - 255) to be assigned.
3 = Microtech (6 digits) - requires a four digit local modifier (0000 - 9999) to be assigned.
NOTE: The local modifier for the Technistore or Microtech reset modes must be assigned after discussion
with the ARC.
67 - Remote Reset

Table of Contents

Other manuals for Honeywell Galaxy Dimension GD-96

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension GD-96 and is the answer not in the manual?

Honeywell Galaxy Dimension GD-96 Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Dimension GD-96
CategoryControl Panel
LanguageEnglish

Related product manuals