EasyManuals Logo

Honeywell GF505 User Manual

Honeywell GF505
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #79 background imageLoading...
Page #79 background image
Master Programming Level Programming
SIA-DCS Format - Secondary Central Station Phone Number
The information shown in Table 3.7 is automatically programmed for the Secondary Central Station phone number Event Codes when
SIA-DCS Format is selected. To disable event reporting, select the desired Event Code to be disabled and press 0 or Clear and then
Enter to disable it. (Enter must be pressed to save the selection. Pressing Escape will not save the selection).
Event Description
Event Code Settings
Active Restoral
Secondary # Zone 1 Alarm FA1 FH1
Secondary # Zone 2 Alarm FA2 FH2
Secondary # Zone 3 Alarm FA3 FH3
Secondary # Zone 4 Alarm FA4 FH4
Secondary # Zone 5 Alarm FA5 FH5
Secondary # Zone 6 Alarm FA6 FH6
Secondary # Zone 7 Alarm FA7 FH7
Secondary # Zone 8 Alarm FA8 FH8
Secondary # Zone 9 Alarm FA9 FH9
Secondary # Zone 10 Alarm FA10 FH10
Secondary # Zone 1 Disabled FB1 FU1
Secondary # Zone 2 Disabled FB2 FU2
Secondary # Zone 3 Disabled FB3 FU3
Secondary # Zone 4 Disabled FB4 FU4
Secondary # Zone 5 Disabled FB5 FU5
Secondary # Zone 6 Disabled FB6 FU6
Secondary # Zone 7 Disabled FB7 FU7
Secondary # Zone 8 Disabled FB8 FU8
Secondary # Zone 9 Disabled FB9 FU9
Secondary # Zone 10 Disabled FB10 FU10
Secondary # Drill FI FK
Secondary # AC Fault AT AR
Secondary # Zone 1 Fault FT1 FJ1
Secondary # Zone 2 Fault FT2 FJ2
Secondary # Zone 3 Fault FT3 FJ3
Secondary # Zone 4 Fault FT4 FJ4
Secondary # Zone 5 Fault FT5 FJ5
Secondary # Zone 6 Fault FT6 FJ6
Secondary # Zone 7 Fault FT7 FJ7
Secondary # Zone 8 Fault FT8 FJ8
Secondary # Zone 9 Fault FT9 FJ9
Secondary # Zone 10 Fault FT10 FJ10
Secondary # Zone 1 Dirty FT1 FJ1
Secondary # Zone 2 Dirty FT2 FJ2
Secondary # Zone 3 Dirty FT3 FJ3
Secondary # Zone 4 Dirty FT4 FJ4
Secondary # Zone 5 Dirty FT5 FJ5
Secondary # Zone 6 Dirty FT6 FJ6
Secondary # Zone 7 Dirty FT7 FJ7
Secondary # Zone 8 Dirty FT8 FJ8
Secondary # Zone 9 Dirty FT9 FJ9
Secondary # Zone 10 Dirty FT10 FJ10
Secondary # Earth Fault ET38 ER38
Secondary # Low Battery Fault YT0 YR0
Secondary # No Battery Fault YT0 YR0
Table 3.7 SIA-DCS Secondary # Event Codes
GF505 & GF510 Manual P/N 53164:B5 6/12/2018