Mounting and installation
6
Creating a zoning plan
Within a building rooms (zones) can be controlled with different room
setpoint temperatures. The thermal actuators of the allocated zone (room)
are controlled depending on the room setpoint temperature.
A maximum of 5 temperature zones can be
set up for each underoor heating controller.
This number can be increased to 8 by
using the expansion module HCS80.
A maximum of 3 thermal actuators
can be connected in each zone.
!
Temperature
zones (maximum)
Thermal actuators
(maximum)
Number of
underfloor heating
controllers
8 24 1
16 48 2
24 72 3
Specifying temperature zones
1
Specify the number of zones and
the corresponding rooms.
2
Allocate the corresponding room device,
for example HCW82 and the required
thermal actuators to each zone.
3
Label the room devices and thermal actuators for the
respective zone (see fold-out page Fig.4, Z1...Z8).
Explanation of the example
t The living area is covered by six temperature
zones. The additional module HCS80
is required for this partitioning.
t The underfloor heating controller
controls 8 thermal actuators.
Dining
Kitchen
Bathroom
Zone 5
Zone 6
Zone 4
Zone 2
Zone 3
Zone 1
Livingroom
Hall
Bedroom
W.C.
Mounting and installation