34 | Performance Series HQA Digital Video Recorder Remote User Guide
Figure 3-1 Camera Conditions Interface
Table 3-1 Camera Conditions
Setting Description
Channel Select a channel from the dropdown list.
Period Divide a day (24-hour period) into two periods, then set
different hue, brightness, and contrast settings for each
period.
Saturation Adjusts monitor window saturation. Select from 0 to 100. The
default setting is 50. The recommended range is 40 to 60.
The higher the number, the stronger the color. This value has
no effect on the general brightness of the video. The video
color might become too strong if the value is too high. Gray
parts of the video might become distorted if the white balance
is not correct.
If the value is too low, the video might be poor.
Brightness Adjusts the monitor window brightness. The default setting is
50.
The higher the number, the brighter the video. When you
select a value, the bright and dark elements of the video are
adjusted. Use this function to adjust video brightness when
the entire picture is too dark or too bright. Select from 0 to 100.
The recommended range is 40 to 60.
Note The video might become hazy if you select a high
brightness value.