LYNX Touch Installation and Setup Guide
- 19 -
Installing Wireless Zones
5800 Series Transmitter Loop Numbers
(Refer to this information when programming transmitters)
The following illustration shows the compatible transmitters, their associated input types and loop
designations.
LOOP 1
5806/5806W3/5807
5808/5808LST/5808W3
EN R OL L A S
SU P ER V IS ED
LOOP 1
LOOP 1
5809
EN R OL L A S
SU P ER V IS ED
58 1 8M N L
EN R OL L A S
SU P ER V IS ED
LOOP 1
LOOP 1
LOOPS
1 - 3
LOOP 1
LOOP 1
5814
EN R OL L A S
SU P ER V IS ED
5800-002-V3
58 0 4B D /5 8 04 B D V
ENROLL AS
BUTTON
PROGRAM HOUSE ID
LOOP 4
LOOP
3
LOOP 1
LOOP 2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5804E
ENROLL AS
BUTTON
58 2 2T
EN R OL L A S
SU P ER V IS ED
58 7 7
58 1 6M N
EN R OL L A S
SU P ER V IS ED
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
LOOP 2
(REED)
LOOP 3
(TERMINALS)
58 2 8/ 5 82 8 V
PR OG R AM
HOUSE ID
58 2 1
EN R OL L A S
SU P ER V IS ED
58 2 0L
EN R OL L A S
SU P ER V IS ED
58 1 9S ( W HS & B R S)
EN R OL L A S
SU P ER V IS ED
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
58 1 9
EN R OL L A S
SU P ER V IS ED
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
58 0 0WAV E
PR OG R AM
HO U SE I D
58 0 0P I R- OD
EN R OL L A S
SU P ER V IS ED
58 0 0P I R/ 58 0 0P I R- C OM
EN R OL L A S
SU P ER V IS ED
58 1 1
EN R OL L A S
SU P ER V IS ED
58 0 0P I R- RE S
EN R OL L A S
SU P ER V IS ED
58 0 0M i cr a
EN R OL L A S
SU P ER V IS ED
58 0 0C O
EN R OL L A S
SU P ER V IS ED
58 0 0S S 1
EN R OL L A S
SU P ER V IS ED
58 0 0R L
SE T H OU S E ID
LOOP 1
LOOP 1
(LOW
SENSITIVITY
LOOP 2
(HIGH
SENSITIVITY)
LOOP 3 (TEMP)
LOOP 4 (TAMPER)
LOOP 1
(HIGH
SECURITY)
LOOP 2
(STANDARD
SECURITY)
LOOP 3 (TILT MODE)
LOOP 4 (TAMPER)
LOOP 1
(LOW
SENSITIVITY
LOOP 2
(HIGH
SENSITIVITY)
LOOP 3 (TEMP)
LOOP 4 (TAMPER)
5834-2
ENROLL AS
BUTTON
5834-4
ENROLL AS
BUTTON
LOOP
1
LOOP
1
LOOP
1
LOOP
1
58 7 8
ENROLL AS
BUTTON
5870API
EN R OL L A S
SU P ER V IS ED
5869
EN R OL L A S
SU P ER V IS ED
58 5 3
EN R OL L A S
SU P ER V IS ED
ARMED
READY
MESSAGE
MIC
LOOP 1
(LOW SENSITIVITY)
LOOP 2
(HIGH SENSITIVITY)
58 9 8
EN R OL L A S
SU P ER V IS ED
LOOP 4
LOOP 1
LOOP 2
LOOP 3
SERIAL #1
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 3
SERIAL #1
LOOP 2
SERIAL #1
LOOP 1
SERIAL #2
LOOP 2
3
AWAY
STAY
1
2
4
OFF
ON
SERIAL #1
LOOP 4
SERIAL #2
LOOP 1
SERIAL #2
LOOP 2
SERIAL #2
LOOP 3
SERIAL #1
LOOP 1
SERIAL #2
LOOP 4
LOOP 3
58 1 6
EN R OL L A S
SU P ER V IS ED
LOOP 1
(TERMINALS)
LOOP 2
(REED)
SERIAL #2
LOOP 1
SERIAL #1
LOOP 3
SERIAL #1
LOOP 2
Notes: (1)
The 5806W3 smoke detector must be used in SIA applications.
(2) Button type devices send only fault and low battery signals; no restore or check-in signals.
Supervised devices send periodic check-in signals, faults, restore and low battery signals.
Unsupervised devices send periodic check-in signals, faults, restore and low battery signals but the control does not supervise
the check-in signals.
(3) If an external sounder is required, the 5800WAVE should be used.
(4) The 5804E and 5834-4 encrypted (High-Security) devices must be activated while the system is in Go-No-Go Test Mode. Refer
to the transmitter’s Installation Instructions for complete details. The system will confirm the enrollment of the encrypted device
by beeping two times
(5) The 5800PIR-OD, 5800RL, 5800SS1, 5804E, 5804BD, 5804BDV, 5814, 5816TEMP, 5821, 5828/5828V, 5877, and 5878
wireless transmitters have not been evaluated by UL/ETL.