LYNX Touch Installation and Setup Guide
- 76 -
Zone Programming Default Values
Zone Programming Notes
1. Zone 1 is a hardwire zone; Zones 95, 96 and 99 are keypad panics.
2. For the LYNX Touch L5210/L5210CN Zones 2 to 64 are RF zones (Zones 46 to 48 are reserved for Garage Door Zones); Zones 140-155
are RF Button Zones and 180-185 are Temperature Zones.
3. For the LYNX Touch L7000/L7000CN Zones 2 to 80 are RF zones (Zones 45 to 48 are reserved for Garage Door Zones); Zones 140-163
are RF Button Zones and 180-187 are Temperature Zones.
4. The default values shown below are for the LYNX Touch L5210/L5210CN.
Zone Assignment/Alarm Response Types for Configuration 1
Zone
Number
Loop
Number
Device Type Response Type
Alarm
Report
Chime Supervision
Arm
Night
Zone Descriptor
1
---
New
Not Used
Yes
Disabled
End of Line
n/a n/a
2
2
Door
Entry Exit 1
Yes
Standard
Supervised
n/a
Front
3
2
Door
Entry Exit 1
Yes
Standard
Supervised
n/a
Back
4
2
Window
Perimeter
Yes
Standard
Supervised
n/a
n/a
5
1
Motion Sensor
Interior With Delay
Yes
Disabled
Supervised
No
n/a
46 1 New Not Used No Standard Supervised n/a
Main
47 1 New Not Used No Standard Supervised n/a
Main
48 1 New Not Used No Standard Supervised n/a
Main
140
3
4 Button
Arm Away
Yes
Disabled
Button
n/a
n/a
141
2
4 Button
Disarm
Yes
Disabled
Button
n/a
n/a
142
4
4 Button
Arm Stay
Yes
Disabled
Button
n/a
n/a
143
1
4 Button
No Response
No
Disabled
Button
n/a
n/a
144
3
4 Button
Arm Away
Yes
Disabled
Button
n/a
n/a
145
2
4 Button
Disarm
Yes
Disabled
Button
n/a
n/a
146
4
4 Button
Arm Stay
Yes
Disabled
Button
n/a
n/a
147
1
4 Button
No Response
No
Disabled
Button
n/a
n/a
180 --- Temperature Monitor Yes Disabled High Temp n/a
n/a
181 --- Temperature Monitor
Yes Disabled Low Temp n/a
n/a
182 --- Temperature Monitor
Yes Disabled High Temp n/a
n/a
183 --- Temperature Monitor
Yes Disabled Low Temp n/a
n/a
184 --- Temperature Monitor
Yes Disabled High Temp n/a
n/a
185 --- Temperature Monitor
Yes Disabled Low Temp n/a
n/a
95
---
Fire
Fire No Verification
Yes
Disabled
Panic Trigger
n/a
n/a
96
---
Medical
Not Used
Yes
Disabled
Panic Trigger
n/a
n/a
99
---
Police
24-Hour Silent
Yes
Disabled
Panic Trigger
n/a
n/a
Zone Assignment/Alarm Response Types for Configuration 2
Zone
Number
Loop
Number
Device Type Response Type
Alarm
Report
Chime Supervision
Arm
Night
Zone Descriptor
1
---
New
Not Used
Yes
Disabled
End of Line
n/a n/a
2
2
Door
Entry Exit 1
Yes
Standard
Supervised
n/a
Front
3
2
Door
Entry Exit 1
Yes
Standard
Supervised
n/a
Back
4
2
Door
Entry Exit 1
Yes
Standard
Supervised
n/a
Garage
5
1
Motion Sensor
Interior With Delay
Yes
Disabled
Supervised
No
n/a
6
1
Smoke Detector
Fire No Verification
Yes
Disabled
Supervised
n/a
n/a
46 1 New Not Used No Standard Supervised n/a
Main
47 1 New Not Used No Standard Supervised n/a
Main
48 1 New Not Used No Standard Supervised n/a
Main
140
3
4 Button
Arm Away
Yes
Disabled
Button
n/a
n/a
141
2
4 Button
Disarm
Yes
Disabled
Button
n/a
n/a
142
4
4 Button
Arm Stay
Yes
Disabled
Button
n/a
n/a
143
1
4 Button
No Response
No
Disabled
Button
n/a
n/a
144
3
4 Button
Arm Away
Yes
Disabled
Button
n/a
n/a
145
2
4 Button
Disarm
Yes
Disabled
Button
n/a
n/a
146
4
4 Button
Arm Stay
Yes
Disabled
Button
n/a
n/a
147
1
4 Button
No Response
No
Disabled
Button
n/a
n/a
180 --- Temperature Monitor Yes Disabled High Temp n/a
n/a
181 --- Temperature Monitor
Yes Disabled Low Temp n/a
n/a
182 --- Temperature Monitor
Yes Disabled High Temp n/a
n/a
183 --- Temperature Monitor
Yes Disabled Low Temp n/a
n/a
184 --- Temperature Monitor
Yes Disabled High Temp n/a
n/a
185 --- Temperature Monitor
Yes Disabled Low Temp n/a
n/a
95
---
Fire
Fire No Verification
Yes
Disabled
Panic Trigger
n/a
n/a
96
---
Medical
24-Hour Auxiliary
Yes
Disabled
Panic Trigger
n/a
n/a
99
---
Police
24-Hour Audible
Yes
Disabled
Panic Trigger
n/a
n/a