LYNX Touch Installation and Setup Guide
- 26 -
Zone Response Type Definitions
Type Function Characteristics
Arm–Stay
Special-purpose zone type used with 5800 Series
wireless button units.
Exit delay regardless of the arming mode selected.
System is armed in the STAY mode when the zone is activated.
Arm–Away
Special-purpose zone type used with 5800
Series wireless button units.
System is armed in the AWAY mode when the zone is activated.
Disarm
Special-purpose zone type used with 5800
Series wireless button units.
Disarms the system when the zone is activated.
No Alarm Response
Assigned when no-alarm response is required No reports to the Central Station.
No keypad sounding or chime
System can still be armed
No display on the screen
Silent Burglary
Usually assigned to sensors or contacts on
exterior doors and windows where sirens are NOT
desired.
Instant alarm, with NO audible indication when armed in the AWAY,
STAY, STAY NO DELAY, NIGHT STAY, or AWAY INSTANT mode.
Report sent to the Central Station.
Monitor Can be assigned to any wireless zone used for
asset protection. Works as a dynamic monitor of a
zone fault/trouble (not alarm).
Reports to the Central Station, if enabled.
Fault/restore events are logged by the system.
Activity Zone No. and Zone Descriptor displayed on LCD.
Restore will be stored in event log.
No keypad sounding or chime
System can still be armed
General Monitor Assigned sensors or contacts on doors and
windows or asset protection within the premises.
Used to track activity of the occupant and alert
occupant of the activity of others.
No reports to the Central Station.
Fault/restore events are logged by the system.
Monitors entry into a monitored area. Activates a one-time
announcement when faulted.
Activity Zone No. and Zone Descriptor displayed on LCD.
General Response Assigned sensors or contacts on doors and
windows or asset protection within the premises.
Used to track activity of the occupant and alert
occupant of the activity of others.
No reports to the Central Station.
Fault/restore events are logged by the system.
Monitors entry into a monitored area. Activates a zone announcement
when faulted.
Activity Zone No. and Zone Descriptor displayed on LCD.
System re-triggers audible sounding every ten seconds until
acknowledged (Off sequence or wireless button).
Resident Monitor Used to monitor a resident in an area deemed to
be dangerous by a caregiver.
No reports to the Central Station.
Monitors entry into a monitored area. Activates a zone announcement
when faulted.
Activity Zone No. and Zone Descriptor displayed on LCD.
Fault/Restore events are not logged by the system.
Resident Response
Used to monitor a resident in an area deemed to
be dangerous by a caregiver. Requires
acknowledgement by caregiver.
No reports to the Central Station.
Monitors entry into a monitored area. Activates a zone announcement
when faulted.
Activity Zone No. and Zone Descriptor displayed on LCD.
System re-triggers audible sounding every ten seconds until
acknowledged (Off sequence or wireless button).
Fault/Restore events are not logged by the system
Trouble Used with Other response type
The system will provide a trouble sounding from the keypad (and a
Central Station report, if desired).
Garage (Burglary) Assigned to Automatic Garage Door applications.
Provides a status of the garage door close/open
real time state
Associated With Entry Delay #2 Programmed Time.
Exit delays when armed in AWAY, STAY or NIGHT STAY mode.
No Entry Delay when armed in Away or Stay Instant modes.
System can be armed with zone in the faulted state. When the zone is
closed it will automatically be inclusive within protection points. If the
point is subsequently violated, it will initiate an alarm.
Garage Monitor Assigned to Automatic Garage Door applications.
Provides a status of the garage door close/open
real time state
Can be assigned to any wireless zone used for automatic “Garage
Door” Open/Close status.
Will not initiate an alarm condition on the control.
When zone is in the open state will display “FAULT.”
Does not report alarms to Central Station.
Zone will chime if enabled to do so
System can be armed if this zone type is in fault

Table of Contents

Other manuals for Honeywell L5210 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell L5210 Series and is the answer not in the manual?

Honeywell L5210 Series Specifications

General IconGeneral
BrandHoneywell
ModelL5210 Series
CategorySecurity System
LanguageEnglish

Related product manuals