LTE-X Series Installation and Setup Guide
– 8 –
PROMPTS
ENTRY
OPTIONS
DESCRIPTION
5
Change Password?
(Y/N)_
[Y], [N]
If a password has already been assigned, this prompt
appears after pressing [N] at the "Program Device?"
prompt.
Press [Y] if you want to change the password.
NOTE: To clear an existing password, without entering
a new one, answer [Y] to the "Change Password?"
prompt, then press the [Enter] key when prompted for
the new password and its confirmation.
6
Enter Password
[0-9, A-F, N, S, T,
X, Y]
This prompt is displayed if [Y] was pressed in Prompt 4
or 5.
Enter a 4-digit password
(0-9, A-F, N, S, T, X, Y).
7
Verify Password
[0-9, A-F, N, S, T,
X, Y]
Re-enter the password as confirmation.
If the password doesn't match the first entry, the
following is displayed followed by the "Exit Prog. Mode?"
prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is displayed
directly.
8
Exit Prog. Mode?
(Y/N)_
[Y], [N]
[ESC]
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting the Programming Mode topic.
9
Multi Mode
(Disabled)_
Disabled
Enhanced
Reports
Disable for normal alarm processing and go to Prompt
11 "Primary City ID" prompt.
Select “Enhanced Reports” if you want system events
sent by e-mail to the user. Enhanced Reports enables
reporting to Total Connect 2.0 web services.
NOTE: To use “Enhanced Reports” ensure the control
panel is Total Connect 2.0 Ready.
10
Multi Mode Addr
(25)
[01-30]
This address must be programmed if using the Multi-
Mode (e-mail notification) feature. The device address
must be unique from the normal communicator (or LRR)
device address and the Keypad Address used for Remote
Access or Direct Wire downloading.
The address used must also be enabled as a 4204 relay
module in VISTA control panels.
NOTE: Account information is provided by the central station administrator.
11
Primary City ID
(??)_
[01-99]
Enter the 2-digit primary city ID,
01-99 (decimal).
12
Primary CS ID
(??)
[01-FE]
Enter the 2-digit primary central station ID number, 01-
FE (HEX).
13
Primary Sub ID
(????)
[0001-9999]
Enter the 4-digit subscriber account number, 0001-9999
(decimal).