EasyManuals Logo

Honeywell LYNX Touch User Manual

Honeywell LYNX Touch
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
24
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
SECURING THE PREMISES
Entry/Exit Delays
Entry/Exit DelaysEntry/Exit Delays
Entry/Exit Delays
system/zone status area. The alarm will continue to sound until the system is disarmed or
timeout ocurs. To stop the alarm, the system must be disarmed by selecting the Disarm
icon OR depressing the Off key and then entering your security code. The message Alarm
Cancelled" is displayed, in the system bar, indicating that the alarm has been cancelled (if
this feature is enabled by the installer). Alarm and the faulted zone continue to be
displayed with their associated icons in the system/zone status area. To clear the display,
select the Disarm icon OR depress the Off key and then enter your security code a second
time. An exit alarm also results if an entry/exit door or interior zone is faulted within two
minutes after the end of the exit delay.
Entry Delays give you time to disarm the system when you re-enter through the designated
entrance door. You must disarm the system before the entry delay period ends, or an alarm
will occur. The control beeps during the entry delay period, reminding you to disarm the
system. There are two entry delays (if programmed). The first is for your primary entrance
and the second can be used for a secondary entrance, where a longer delay is required to
walk to the control to disarm the system. You can also arm the system with no entry delay at
all by selecting the Delay icon prior to arming the system. This will toggle the system to
Instant, which can provide greater security while on the premises or while away for
extended periods of time. See ARMING THE SYSTEM section for procedure. See your
installer for delay times programmed for your
system.
Exit Delay:
None, 30, 45, 60, 90 seconds, 2 minutes
Entry Delay 1:
None, 30, 45, 60, 90 seconds, 2 minutes
Entry Delay 2:
None, 30, 45, 60, 90 seconds, 2 minutes
LYNX Touch SIA Exit/Entry Delay Times
Exit Delay:
45, 60, 90 seconds, 2 minutes
Entry Delay 1:
30, 45, 60, 90 seconds, 2, 3, 4 minutes
Entry Delay 2:
30, 45, 60, 90 seconds, 2, 3, 4 minutes

Other manuals for Honeywell LYNX Touch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell LYNX Touch and is the answer not in the manual?

Honeywell LYNX Touch Specifications

General IconGeneral
ZonesUp to 64 wireless zones
Voice ControlNo
Remote ControlYes, via mobile app
Keypad ZonesNo
PartitionsNo
Voice PromptsYes
Built-in Z-WaveYes
DisplayColor touchscreen
CommunicationCellular
Wireless Zones64
AutomationZ-Wave
Siren OutputBuilt-in
Wireless Frequency345 MHz
Supported Security DevicesDoor/window sensors, motion detectors
CompatibilityHoneywell 5800 series wireless devices