EasyManua.ls Logo

Honeywell N3680 - Page 162

Honeywell N3680
203 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
146 N3680 Decoded Engine User Guide
This response indicates that Codabar Coding Enable (CBRENA) has a range of val-
ues from 0 to 1 (off and on).
Example: What is the default value for Codabar Coding Enable?
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example: What is the device’s current setting for Codabar Coding Enable?
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on.
Example: What are the device’s settings for all Codabar selections?
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set:
To 1, or on
The Start/Stop Character (SSX) is set to 0, or Don’t Transmit
The Check Character (CK2) is set to 0, or Not Required
Concatenation (CCT) is set to 1, or Enabled
The Minimum Message Length (MIN) is set to 2 characters
The Maximum Message Length (MAX) is set to 60 characters
Default setting (DFT) has no value.
Enter: cbrena*.
Response: CBRENA0-1[ACK]
Enter: cbrena^.
Response: CBRENA1[ACK]
Enter: cbrena?.
Response: CBRENA1[ACK]
Enter: cbrena?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].

Table of Contents

Related product manuals