NFS2-640 UL Listing Document — P/N 52741LD:H9 5/19/2022 39
AEM-32A Annunciator Expander Module O O O O O O O O O
AFM-16A Annunciator Fixed Module O O O O O O O O O
AFM-16AT Annunciator Fixed Module O O O O O O O O O
AFM-32A Annunciator Fixed Module O O O O O O O O O
AKS-1 Annunciator Key Switch O O O O O O O O O
RKS-S Remote Security Keyswitch O O O O O Y O O O
ACM-24AT Annunciator Control Module O O O O O O O O O
AEM-24AT Annunciator Expander Module O O O O O O O O O
ACM-48A Annunciator Control Module O O O O O O O O O
AEM-48A Annunciator Expander Module O O O O O O O O O
FDU-80 Annunciator O O O O O O O O O
LCD-80 Annunciator O O O O O O O O O
LCD-80TM Annunciator O O O O O O O O O
LCD2-80 Annunciator O O O O O O O O O
RPT-W Repeater Wire O O O O O O O O O
RPT-F Repeater Fiber O O O O O O O O O
RPT-485W Repeater Wire O O O O O O O O O
RPT-485FW Repeater Wire/Fiber O O O O O O O O O
FFT-7 Firefighter’s Telephone O O O O O O O O O
FFT-7S Firefighter’s Telephone O O O O O O O O O
FHS Fireman’s Handset O O O O O O O O O
FPJ Fireman’s Phone Jack O O O O O O O O O
NBG-12LX Addressable Manual Pull Station O O O O O O O O O
NBG-12LRA Agent Release Abort Station O O O O O O O O O
RM-1, RM-1SA Remote Microphone O O O O O O O O O
BP2-4 Battery Plate Y Y Y Y Y Y Y Y Y
FCO-851
IntelliQuad PLUS Multi-Criteria Fire/CO
Detector
OOOOO OOO O
FSA-8000 Intelligent Aspiration Detector O O O O O O O O O
FSA-20000P Intelligent Aspiration Detector O O O O O O O O O
KEY:
Y = Yes N = No O = Optional
Notes:
1. The system must contain either one or the other displays.
2. The system must contain at least one of the units.
3. When used with the DAA, DAA2, DAX or DS-DB, the system must use the NCA-2/C or the NCD as the display.
4. Each unit must include at least one enclosure.
5. Various dress panels/dead fronts/ trim rings must be employed so that internal components and high voltage is not accessible.
6. Also required when devices for Carbon Monoxide signaling are employed.
7. .Required if utilizing a central station other than supported by CGW-MB
Alarm verification (maximum verification period of 60 for field programmable between 0 and 60s)
Supports standard 2-wire smoke detectors using Models FZM-1. refer to the Device Compatibility Document for compatible 2-wire smoke detectors
Supports addressable or analog devices
Field Programming
Signal Silence Inhibit
Remote annunciator outputs
Automatic Alarm Signal Silence
Drift compensation
Detector sensitivity testing per Par. 7-3.2.1 of NFPA 72GW-MB alone OR using a CGW-MB with CGW-PT OR using CGW-DACT.
8. Required when using CGW-MB alone OR using a CGW-MB with CGW-PT OR using CGW-DACT.
Module Description CS Local AUX RS P (PPU) P(Burg) REL P Rec
Process
Mana.
Table 12 System Configuration (3 of 3)

Other manuals for Honeywell Notifier NFS2-640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Notifier NFS2-640 and is the answer not in the manual?

Honeywell Notifier NFS2-640 Specifications

General IconGeneral
BrandHoneywell
ModelNotifier NFS2-640
CategoryControl Panel
LanguageEnglish

Related product manuals