24 
APPLICATIONS AND PROTOCOLS 
 
The model number on each scanner includes the scanner number and factory 
default communications protocol. 
 
S
CANNER 
V
ERSION 
IDENTIFIER 
COMMUNICATION PROTOCOL(S) 
38 
RS232 Low Speed USB,  
Keyboard Emulation or Serial Emulation 
41  Full RS232C/Light Pen Emulation 
47 
Keyboard Wedge, Stand-Alone Keyboard and  
RS232 Transmit/Receive 
MS7120 
106  RS485 and Full Speed USB 
 
 
The MS7120 scanner with built-in PC Keyboard Wedge Interface is designed to 
be used for keyboard emulation only.  Many RS232 configurable  
functions (e.g. formatting) available in other Honeywell scanners are also 
available as keyboard wedge functions. 
 
The following are the most important selectable options specific to the keyboard 
wedge. 
 
Keyboard Type 
 
 
  ** AT (includes IBM
®
 PS2 models 50, 55, 60, 80) 
  IBM PS2 (includes models 30, 70, 8556) 
 
Keyboard Country Type 
 
 
 USA **   Italian   Swiss 
 Belgium   Japanese   Sweden/Finland 
 French   Russian Cryillic   Turkish 
 German   Slovenian   United Kingdom 
 Hungarian   Spanish 
 
 
 
**  Default setting.  Refer to the MetroSelect
®
 Configuration Guide  
(
PN 00-02407) or MetroSet2’s help files for information on how to change the 
default settings.