UPGRADING THE FIRMWARE 
 
The MS7120 is part of Honeywell’s line of scanners with flash upgradeable 
firmware.  The upgrade process requires, a new firmware file supplied to the 
customer by a customer service representative
 and Honeywell’s MetroSet2 
software
.  A personal computer running Windows 95 or greater with an 
available RS232 serial or USB port is required to complete the upgrade.   
 
 
PowerLink Cable #54-54014 is required when using RS232 for the 
upgrade process.  This cable can be ordered by a customer service 
representative.  Do not use the standard cable supplied with keyboard 
wedge or RS485 scanner interface kits.  If using USB for the upgrade 
process, the standard USB cable provided with the scanner can be 
used. 
 
To upgrade the firmware in the MS7120: 
 
1.  Plug the scanner into a serial communication port on the host system. 
2.  Start the MetroSet2 software. 
3.  Click on the plus sign (+) next to POS Scanners to expand the supported 
scanner list. 
4.  Choose the MS7120 Orbit or Orbit (L+)* from the list. 
5.  Click on the C
onfigure Orbit/7120 (L+)* Scanner button. 
6. Choose Flash Utility from the options list located on the left side of the 
screen. 
7.  Click on the Open File button in the Flash Utility window. 
8.  Locate and open the flash upgrade file supplied. 
9.  Select the COM port that the scanner is connected to on the host system. 
10.  Verify the settings listed in the Flash Utility window. 
11.  Click on the Flash Scanner button to begin the flash upgrade. 
12.  A message will appear on the screen when the upgrade is complete.  
 
 
 
 
 
 
 
See Customer Support on page 37. 
 
 
MetroSet2 is available for download, at no additional cost, from 
www.honeywellaidc.com 
* Revision L or later. 