PX940 Applicator Interface Installation Instructions 21
Example:
•...
100 ON PORTIN.REPRINT GOSUB 150
...
150 PRINTFEED -1,1
160 RETURN
Printfeed
The dataready signal must be set manually by the Fingerprint application
before a printfeed is issued when using with an applicator.
Handling External Applicator Errors
When an error signal (apperr1, apperr2, or apperr3) is received, the application
moves to a specified subroutine that takes action based on error severity.
Example
•...
60 ON PORTIN.APPERR1 GOSUB 100
...
100 perform error handling
110 RETURN
Handling Internal System Errors
For internal system errors, the system error signal status can be read at any
time within the application so appropriate measures can be taken. When any of
these errors occur, the appropriate out signal (including the error) is asserted:
Printhead lifted
Ribbon out
Media out
General print engine fault
•Front arm lifted
Verifier calibration required
Verifier calibration expired
Exceed maximum barcodes
Verifier hardware error
Verifier failure action prompt
Example
10 IF PORTIN.RIBBONLOW GOTO 200
...