T6R-2Z-EN0H 8603 NL01 R0718
2-zone application
2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX
APPLICATION MANUAL
With the new 2-channel Receiver box (R6H911RF) and
2x a T6R wireless smart thermostats (T6H700RW)
automatic time and temperature control of 2 heating
zones and a boiler for homes and apartments can be
managed.
It’s compatible with 24-230V on/off and OpenTherm®
appliances such as gas boilers, combi-boilers and heat
pump. Also works with zone valve applications but not
with electric heating (240V).
The solution is designed with the installer in mind.
The 2-channel Receiver box offers mounting options for
directly on the wall or on a wall box. Wiring can be from
below or from the back by lifting the terminal platform,
which makes installation quick and easy.
The T6R wireless thermostat has a high contrast PMVA
display with dynamic text line and touch screen buttons.
The thermostat has a simple programming philosophy to
make it easier to install and very user friendly.
The 2-zone solution is ideal for consumers who want to
split the comfort control of their home in 2 areas, like
upstairs and down-stairs or a living and working area.
The solution offers remote comfort control of both zones
via the Honeywell Home app.
FEATURES
T6R Smart Thermostat
Attractive, ultra-modern styled thermostats make it ideal for
any location in any type of home.
Wireless with table stand to fit a new and retrofit
installations.
Wi-Fi communication to connect to the Internet
- Smart Home and Apple HomeKit ready
A dynamic text display on the LCD that gives enhanced
feedback to the user / installer.
High LCD Contrast and backlighting for easier viewing in all
light conditions.
Time out screen with selectable brightness
Factory programmed daily or 5+2 default heating schedule.
Schedule with up to 6 independent time and temperature
pairs to suit the comfort needs.
Hold until temperature override of programmed schedule
temperature till the next switch point.
Schedule off mode for manual operation.
Setpoint and room temperature always displayed.
OFF position has an integral frost protection setting at
minimum 5C so that pipes in the house will never freeze in
winter.
Alert messages to assist in fault-finding.
Honeywell Home mobile App for:
- Remote view and change of settings
- Schedule changes
- Smartphone Geolocation temperature control
User menu allows extra functions to be set at the discretion
of the user:
- Language selection
- Wi-FI setup
- Optimisation
- Clock setting
- Resetting the heating program to factory default
- Brightness
- Temperature offset
- Lock function
Advanced menu (Installer Set-Up) allows extra functions to
be set at the discretion of the installer to match the
consumers applications and needs:
- System type
- OpenTherm data
- Upper / Lower Set point Limit Adjust
- Minimum ON time
- Cycle rate
- Factory Reset
- Binding
2-channel Receiver box
Clear LED indication of bound devices
Override button per zone with LED indication
Simple binding via override button
A flip up wiring platform for easy wiring
Pinhole for easy reset.
2 on/off relay outputs
OpenTherm
®
compatible heating control output.

Questions and Answers:

Honeywell R6H911RF Specifications

General IconGeneral
Programming7-Day Programmable
BacklightYes
Hold FeatureYes
Filter Change AlertYes
TypeProgrammable
Power SourceBattery
DisplayDigital

Summary

FEATURES

T6 R Smart Thermostat

Lists key features of the T6R Smart Thermostat, including its design and connectivity.

2-channel Receiver box

Highlights features of the 2-channel Receiver box, such as LED indicators and wiring ease.

T6 R THERMOSTAT DISPLAYBUTTON LAYOUT

Reference to the icons

Explains the meaning of various icons used on the T6R thermostat display.

2-CHANNEL RECEIVER BOX

Status LED and Controls

Describes the status LED, binding mode, and manual override features of the receiver box.

WIRING OPTIONS 2-CHANNEL RECEIVER BOX

Wiring 2 zone valves (230 V) and basic 230 V onoff boiler

Wiring diagram for 230V zone valves and an on/off boiler.

Wiring 2 zone valves (230 V) and OpenTherm boiler

Wiring diagram for 230V zone valves and an OpenTherm® boiler.

Wiring 2 zone valves (24 V) and 24 V onoff boiler

Wiring diagram for 24V zone valves and an on/off boiler.

Wiring 2 zone valves (24 V) OpenTherm boiler

Wiring diagram for 24V zone valves and an OpenTherm® boiler.

MOUNTING AND WIRING 2-CHANNEL RECEIVER BOX

Opening and removing top cover

Instructions for opening and removing the top cover of the receiver box.

Wall box or Rear wiring

Instructions for wall box or rear wiring of the receiver box.

Surface wiring

Instructions for securing surface wiring using cable clamps.

Replace cover

Instructions for closing and securing the receiver box cover.

POWER UP 2-CHANNEL RECEIVER BOX

Binding requirement

Notes that thermostats need to be bound to the receiver box after power up.

T6 R THERMOSTAT SET UP AND BINDING

Zone 1 Thermostat setup and binding

Step-by-step guide for powering up, setting up, and binding the first zone thermostat.

Receiver box binding mode

Instructions for putting the receiver box into binding mode for thermostat pairing.

Binding process and troubleshooting

Details the binding success/failure indicators and common troubleshooting steps.

Zone 2 Thermostat powering up, setup and binding

Zone 2 thermostat setup steps

Step-by-step guide for powering up, setting up, and binding the second zone thermostat.

Receiver box binding mode for Zone 2

Instructions for putting the receiver box into binding mode for the second thermostat.

Binding success indicators

Details the binding success indicators for the second zone thermostat.

ADVANCED MENU

Menu item descriptions

Explains each menu item and its default settings and options.

Special Features

Provides detailed descriptions of special features like Heat Range and Optimisation.

OPENTHERM COMMUNICATION

Modulating control

Explains how the thermostat controls modulating appliances for accurate temperature.

Low Load Control

Describes the low load control algorithm for boiler performance.

Hot water control

Details how the thermostat manages hot water savings.

OpenTherm data

Explains the appliance data viewable via OpenTherm® communication.

HEAT DEMAND CONTROL

Control based on boiler type

Explains heat demand control for ON/OFF and OpenTherm® boilers.

ONOFF controlled boiler

Describes boiler control for ON/OFF boilers using zone valve end switches.

OpenTherm controlled boiler

Describes boiler control for OpenTherm® boilers comparing zone demands.

SPECIFICATIONS

T6 R Thermostat Specifications

Lists technical specifications for the T6R thermostat.

Receiver box Specifications

Lists technical specifications for the 2-channel receiver box.

Environmental and standards

Details environmental compliance and operating conditions.

RF specifications

Details RF communication band, protocol, and range.

TROUBLE SHOOTING

Receiver box symptoms

Lists common receiver box fault symptoms and possible causes.

Thermostat alert messages

Lists common thermostat alert messages and their remedies.