| Type | Oil Primary Control |
|---|---|
| Frequency | 50/60 Hz |
| Mounting | Panel or surface mount |
| Switch Action | SPDT |
| Ignition Type | Intermittent |
| Voltage | 120V AC |
| Operating Temperature Range | -40°F to 150°F (-40°C to 65°C) |
| Display | LED |
| Flame Failure Response Time (FFRT) | 0.8 seconds |
| Lockout | Manual reset |
| Approvals | UL, CSA |
| Voltage Rating | 120V AC |
Facilitates purging air from oil lines and filters via a purge routine.
Describes interactions with the advanced interface home screens and button functions.
Control recovers from Soft Lockout when the error clears or after a set time.
Control is in Hard Lockout; reset by holding the "i" button for at least 2 seconds.
Returns to Standby from Hard Lockout by holding the "i" button for over 10 seconds.
Enter Installer Setup by pressing all three buttons simultaneously for 2 seconds.
Options to QUIT (re-baseline) or CONTINUE into Installer Setup.
Adjustments for Valve On Delay, Ignition Time, and Burner Off Delay.
Configure TT terminals, spark control, appliance type, and allowed resets.
Enable diagnostics, error history, and exit installer setup.