86
MAN0530 Issue 09 October 03 Searchline Excel
2104M0506
8. CERTIFICATION
8.2.2 Receiver Details
Open-Path
Receiver
EEx d IIC T5 (-40 to +65 C)
o
EEx d IIC T6 (-40 to +40 C)
II 2G
V max. = 32V
o
M20 gland
EEx d, EEx e
Flexible Conduit 900mm long
(see table of Conduit
Technical Characteristics)
M20 gland EEx e
(customer supply)
Certified M25
blank fitted
M20 gland
EEx d, EEx e
Certified M20
blank fitted
IS Cable
Length 15m max.
DVC100 Termination Unit
EEx ia e m IIC
T6 (-40 to +65 C)
o
V max. = 50V,
Imax.=5A
Cable glands M20/M25
SHC1 Handheld
Interrogator
EEx ia IIC
T4 (-40 to +40 C)
o
Cross-Duct
M20 gland
EEx d, EEx e
Flexible Conduit 900mm long
(see table of Conduit
Technical Characteristics)
M20 gland
EEx d, EEx e
IS Cable
Length 15m max.
DVC100 Termination Unit
EEx ia e m IIC
T6 (-40 to +65 C)
o
V max. = 50V,
Imax.=5A
Cable glands M20/M25
SHC1 Handheld
Interrogator
EEx ia IIC
T4 (-40 to +40 C)
o
M20 gland EEx e
(customer supply)
Transmitter
EEx d IIC T5 (-40 to +65 C)
o
EEx d IIC T6 (-40 to +40 C)
II 2G
V max. = 32V
o
Receiver
EEx d IIC T5 (-40 to +65 C)
o
EEx d IIC T6 (-40 to +40 C)
II 2G
V max. = 32V
o
Note:
Later units
1
/
2
" NPT
Note:
Later units
1
/
2
" NPT

Related product manuals