Page 122  Foundation Fieldbus RMA803 Remote Indicator User's Guide  Revision 4 
Conditions of Use “for Ex Equipment”, Hazardous 
Location Equipment or “Schedule of Limitations” 
a.  Consult the manufacturer for dimensional information on the flameproof joints for 
repair. 
b.  Painted surface of the RMA 800 series may store electrostatic charge and 
become a source of ignition in applications with a low relative humidity less than 
approximately30% relative humidity where the painted surface is relatively free of 
surface contamination such as dirt, dust or oil. Cleaning of the painted surface 
should only be done with a damp cloth. 
c.  The ambient temperature range, maximum process temperature and applicable 
temperature class of the equipment is as follows: 
RMA801: T4 for -50˚C < Ta < 85˚C 
RMA803: T4 for -20˚C < Ta < 70˚C 
 
d.  The RMA800 series enclosure contains aluminum and is considered to present a 
potential risk of ignition by impact or friction. Care must be considered during 
installation and use to prevent impact or friction to avoid impact. 
e.  If a charge-generating mechanism is present, the exposed metallic part on the 
enclosure is capable of storing a level of electrostatic charge that could become 
incendive for IIC gases. Therefore, the user/installer shall implement precautions 
to prevent the buildup of electrostatic charge, e.g. earthing the metallic part. This 
is particularly important if the equipment is installed in a zone 0 location. 
f.  On installation, the RMA800 series shall be provided with supply transient 
protection external to the apparatus such that the voltage at the supply terminals 
of the RMA800 series does not exceed 140% of the voltage rating of the 
equipment.