04/08 UDC3200 Universal Digital Controller Operator Manual 5
2 Installation
2.1 Pre-installation Information
2.2 Model Number Interpretation
Instructions
Select the desired key number. The arrow to the right marks the selection available.
Make the desired selections from Tables I through VI using the column below the
proper arrow. A dot ( ) denotes availability.
Key Number
- - - -
_
_ _ _
_
-
_
_
_ _ _ _
_
_
_
I
_
_
_
IIIII IV
_
_
V
_
_ _
_
VI
KEY NUMBER - UDC3200 Single Loop Controller
Selection
Digital Controller for use with 90 to 264Vac Power DC3200
Digital Controller for use with 24Vac/dc Power DC3201
TABLE I - Specify Control Output and/or Alarms
TABLE II - Communications and Software Selections
0 _ _ _
1 _ _ _
2 _ _ _
3 _ _ _
_ 0 _ _
_ A _ _
_ B _ _
_ C _ _
No Selection
_ _ 0 _
_ _ _ R
C _
E _
Math Option
Set Point Programming (1 Program, 12 Segments)
Set Point Programming Plus Math
Current Output (4 to 20ma, 0 to 20 ma)
T _
R _
_ E
_ A
No Additional Outputs or Alarms
Output #1
Software Selections
Standard Functions, Includes Accutune
Open Collector Plus Alarm 1 (5 Amp Form C Relay)
_ T
Output #2 and Alarm
#1 or Alarms 1 and 2
_ B
One Alarm Relay Only
Availability
Infrared Interface Included (Can be used with a Pocket PC)
_ 0
E-M Relay (5 Amp Form C) Plus Alarm 1 (5 Amp Form C Relay)
Solid State Relay (1 Amp) Plus Alarm 1 (5 Amp Form C Relay)
Electro Mechanical Relay (5 Amp Form C)
Solid State Relay (1 Amp)
None
A _
Description
Infrared interface
Reserved
Open Collector transistor output
Dual 2 Amp Relays (Both are Form A) (Heat/Cool Applications)
Communications
Auxiliary Output/Digital Inputs (1 Aux and 1 DI or 2 DI)
RS-485 Modbus Plus Auxiliary Output/Digital Inputs
10 Base-T Ethernet (Modbus RTU) Plus Auxiliary Output/Digital Inputs
TABLE III - Input 1 can be changed in the field using external resistors
1 _ _
2 _ _
3 _ _
Carbon, Oxygen or Dewpoint (Requires Input 2)
1 6 0
_ 00
_ 10
_ 20
Slidewire Input (Requires two Relay Outputs) _ 40
None
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA, 0-10V
Input 1
Input 2
TC, RTD, mV, 0-5V, 1-5V
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA, 0-10V