Do you have a question about the Honeywell UDC330E and is the answer not in the manual?
| Category | Controller |
|---|---|
| Type | Universal Digital Controller |
| Mounting | Panel Mount |
| Input Types | Thermocouple, RTD, mA, V |
| Output Types | Relay, mA, V |
| Control Mode | On/Off, PID |
| Display | Dual 4-digit LED |
| Power Supply | 100-240 VAC |
| Communication Protocols | RS-485, Modbus |
| Temperature Range | Depends on input type |
| Operating Temperature | 0 to 50 °C |
Honeywell's warranty terms and conditions, including remedy for defective materials and workmanship.
Summary of the manual's content, covering installation, configuration, and operation of the UDC3300 controller.
Provides Honeywell's World Wide Web sites and telephone numbers for customer support.
Details the controller's features, accuracy, and conformity with European directives.
Describes the operator interface displays, indicators, and the function of each control panel key.
Details controller mounting requirements, panel cutout dimensions, and physical installation methods.
Covers electrical considerations, safety precautions, grounding, noise reduction, and wiring practices.
Wiring diagrams for inputs, outputs (Time Prop, Current, Position), auxiliary, and communications.
Details digital input connections and wiring for 4-20 mA transmitter power.
Information on control and alarm relay contact configurations and operating states.
Introduces configuration, set up groups, prompts, and the step-by-step configuration process.
Setup parameters for Loop 1 tuning constants including Proportional Band, Reset, and Cycle Time.
Setup parameters for Loop 2 tuning constants including Proportional Band, Reset, and Cycle Time.
Configuration options for Setpoint Ramp Rate, Single Setpoint Ramp, and Ramp/Soak Programming.
Parameters for Accutune, including Fuzzy Overshoot Suppression and tuning criteria.
Configuration of control algorithms, PID loop selection, and output override settings.
Setup parameters for Loop 1 and Loop 2 output algorithms, relay states, and type.
Details setup parameters for Input 1, Input 2, and Input 3, including type, range, and filters.
Setup parameters for Loop 1 and Loop 2 control functions, including PV source, PID sets, and limits.
Details controller power-up, diagnostics, monitoring operator interface, and viewing parameters.
Lists and explains diagnostic error messages and troubleshooting references.
Step-by-step guide for starting up the controller and performing initial tuning.
Covers operating modes, setpoint types, and changing local setpoints.
Shows setpoint indication and procedures for using two sets of tuning constants.
Details alarm setpoints and rules for operating two independent or cascade control loops.
Rules for independent and internal cascade operation of two control loops.
Table for loop selections and rules for high/low output override.
Procedures for selecting loop algorithms, parameters, tuning, and monitoring.
Covers selecting tuning parameters and monitoring two loops with display indications.
Covers modes, setpoints, Accutune, programming, and digital inputs for dual loops.
Covers output override selection and displaying motor position for 3PSTEP control.
Details input math algorithms, selections, and 8-segment characterization.
Describes flow totalizer function, alarms, and digital input reset for totalizers.
Details digital input option and combinations for remote switching.
Minimizes overshoot after setpoint changes or process disturbances.
Table of rules and regulations for TUNE, SP, and PV adaptive tuning.
Procedures for starting, aborting, and tuning duplex (heat/cool) control.
Procedures for using TUNE or SP tuning at start-up for duplex applications.
Details SP tuning behavior after start-up, aborting SP tuning, and the retuning process.
Explains TUN+PV or SP+PV tuning based on process variable disturbances.
Information on PV tuning indications and how to abort PV adaptive tuning.
Procedure for setting or changing the controller's security code.
Configures the rate of change for local setpoints and sets up a single ramp over time.
Guides on programming segments, data configuration, worksheet use, and power outage behavior.
Lists and explains functions required to run and monitor setpoint programs.
Calibrates Position Proportional output for accurate relay operation and slidewire position.
Step-by-step guide for calibrating control outputs using auto/manual modes.