VISTA-15P/20P/SIA Installation and Setup Guide
2
System Features (Continued)
Compatible Devices
6150 Fixed-Word Keypad, 6160 Alpha Keypad, 6150V Fixed-
Word Display Voice Keypad, 6160V Alpha Display Voice
Keypad, 6150RF Keypad/Transceiver. Keypads must be set
for addresses 16-23 (first keypad is address 16) and
programmed in data fields *190-*196.
Touch Screen (AUI) Devices
Touch Screen (AUI) devices are in addition to the 8
addressable keypads. E.g., 6280, Tuxedo Touch
4219, 4229 Zone Expander
Modules
Up to 5 for
up to 40
exp. zones
Up to 2 for
up to 16
exp. zones
Zone numbers are predefined according to the device
addresses used. See Expander Module Addresses table in
Wiring section and set addresses accordingly. Zone Expander
Modules must be set for specific addresses 07-11 based on
zone numbers used.
Uses 5881/5883 Series Receivers/Transceivers.
Use any combination of 4204, 4229 .
Map output devices via *79 Menu mode and defined in *80
Output Functions. 4204 Relay Modules must be set for
specific addresses 12-15.
Can be used to reset 4-wire smoke detectors.
Relays are mapped in *79 and programmed in output functions
via *80 Menu Mode.
Can drive the compatible sounders; steady output for
burglary/panic, or temporal pulse (3 pulses – pause – 3 pulses
– pause – 3 pulses. . .) for fire. Uses current limiting circuitry
for protection.
12VDC, 600mA maximum; uses circuit protection.
Rechargeable (sealed lead-acid type) 12VDC, 4AH minimum.
AlarmNet 7847i, 7847i-E,
LTE-iV, LTE-iA, LTE-XV,
LTE-XA, LTE-XCgsm
Communicators use ECP address 3 to report signals to central
station. If using Total Connect, additional addresses are
enabled; 25 for RIS and an AUI address, 1, 2, 5, or 6 (20P); 1
or 2 (15P).
Plug-in 120VAC transformer, 1321 (1321CN in Canada)
NOTE: All devices and accessories used in a Canadian installation must be Listed for use in Canad