Wiring for the Remote Keyswitch
To install the ADEMCO 4146 keyswitch, perform the following steps:
Step Action
1 Connect the ADEMCO 4146 to the panel as shown in Figure 3-23.
2 If you are using the tamper, make sure it is connected to a zone.
4146 KEYSWITCH
(READY)
GREEN
(ARMED)
RED
TO ZONE 8 + (TERM 27)
TO OUT 5 (J2 PIN 6)
TO ZONE 7 + (TERM 25)
TO ZONE 7/ZONE 8 - (TERM 26)
TO GND (J2 PIN 8)
TO OUT 1 (J2 PIN 7)
4146_keyswitch-001-V0
2000
OHMS
EOLR
2000
OHMS
820
OHMS
820
OHMS
TAMPER
SWITCH
(N.C.)
LOCK
SWITCH (N.O.)
Figure 3-23: Remote Keyswitch Wiring
Installing a Remote Keypad Sounder (For Commercial Burglary use only)
An optional Amseco PAL 328N Piezo Sounder can be used to duplicate the sounds produced by the keypad’s built-in
sounder. The remote sounder will duplicate all sounds (such as alarms, trouble beeps, etc.) except for the short beeps
associated with keypad key depression. One application of this feature would be to produce chime beeps at a distant
location from the keypads.
If used, program field 320 must be set to “0” and field 15 must be set to the desired partition number.
The remote sounder must be connected to the Output 5 on the J2 connector as shown in Figure 3-24.
1 2 3 4 5 6 7 8 9
(GRAY)
(YELLOW)
(WHITE)
(RED)
(VIOLET)
(GREEN)
(BROWN)
BLUE
BLACK
J2 CONNECTOR
AMSECO PAL-328N
PIEZO SOUNDER
(10MA)
4142TR CABLE
J2_trigcon-006-V0
GROUND
OUT 1
OUT 5
OUT 2
INPUT 1
OUT 6
OUT 3
OUT 7
OUT 4
BLACK
RED
_
+
Figure 3-24: Remote Keypad Sounder Wiring