108 Xenon/Granit User Guide
Auto Reconnect Mode
Auto Reconnect controls whether or not the scanner automatically begins the 
relink process when a loss of connection is detected. When the Auto Reconnect On 
bar code is scanned, the scanner begins the relink process immediately, without 
user intervention. Default = Auto Reconnect On.
The table below shows the results of the Auto Reconnect On and Off settings: 
Maximum Link Attempts
The Maximum Link Attempts setting controls the number of times the scanner 
tries to form a connection with a base. During the connection setup process, the 
scanner transmits in order to search for and connect to a base. In order to prevent 
continuous transmissions that could interfere with other users of the ISM band, 
the number of attempts to connect is limited by this setting. After the maximum 
Event Auto Reconnect On Auto Reconnect Off
Scanner out of range Relink occurs automatically. If 
maximum number of link attempts 
is unsuccessful, then the scanner 
must be relinked by either pulling 
the trigger or placing the scanner 
in the base. (See Maximum Link 
Attempts on page 108.)
The scanner is relinked by 
pulling the trigger.
Base reset (firmware 
upgrade or power cycle)
Scanner behaves as if out of range. No attempt to relink made 
while base is powered off. 
Trigger must be pulled to 
initiate relinking.
Scanner power down due to 
Power Time-Out Timer 
setting 
Trigger must be pulled or the scanner must be placed in the base unit 
to relink.
(Note: scanner relinks on power up, but powers on due to one of the 
above actions.)
Scanner reset due to 
firmware upgrade
Relink occurs automatically.
Scanner reset due to instant 
charge pack change
Relink occurs automatically.
Scanner placed in different 
base unit
Relink to new base occurs automatically.