Honeywell Process Solutions Wireless Dual Analog Input Interface Transmitter
Rev. 8 User Manual III
July 2012
Table of Contents
Section 1: Introduction ____________________________________ 1
1.1: Using This Manual 1
1.2: About the Device 2
1.3: Unpacking 2
1.4: Software Compatibility 2
Section 2: Quick Start _____________________________________ 3
Section 3: Installation _____________________________________ 4
3.1: Mechanical Installation 4
3.1.1: Transmitter Positioning 4
3.2: Testing Communications 7
3.2.1: Transmitter RSSI Diagnostics 7
3.2.2: Link Test 8
3.3: Electrical Installation 13
3.3.1: Electrical Specifications 13
3.3.2: Wiring the Voltage/Current Input 13
3.3.3: Wiring the Input Switches 14
Section 4: General Configuration __________________________ 15
4.1: Transmitter Displayed Messages 15
4.1.1: The Read-Only Sequence 15
4.2: Overall Configuration Menu Map 16
4.3: Setting the Transmitter Tag Name 16
4.4: Setting a User Password 17
4.5: Resetting All Transmitter Settings 17
Section 5: Configuring the RF Communications ______________ 18
5.1: RF Channel Selection 18
5.2: RF Baud Rate Selection 19
5.3: RF Identification Selection 19
Section 6: Configuring the Sampling and Transmission Rates ___ 21
6.1: Selecting the Normal Transmission Rate 21
6.1.1: Configure the Normal Transmission Rate from the Transmitter 22
6.1.2: Configure the Normal Transmission Rate Using WMT 22
6.2: Selecting the Normal Sampling Rate 23
6.2.1: Selecting the Normal Sampling Rate from the Transmitter 24
6.2.2: Configure the Normal Sampling Rate Using WMT 24
6.3: Selecting the Abnormal Transmission Rate 25
6.3.1: Configure the Abnormal Transmission Rate from the Transmitter 25
6.3.2: Configure the Abnormal Transmission Rate Using WMT 26
6.4: Selecting the Abnormal Sampling Rate 27
6.4.1: Configure the Abnormal Sampling Rate from the Transmitter 27
6.4.2: Configure the Abnormal Sampling Rate Using WMT 28
6.5: Setting the Smart Rate Threshold 29
6.5.1: Configure the Smart Rate Using WMT 29
6.6: Selecting the Normal Upper and Lower Values 30
6.6.1: Configure the Upper and Lower Limits from the Transmitter 30
6.6.2: Configure the Upper and Lower Limits Using WMT 31
6.7: Selecting Rates, Thresholds, and Deadbands via the Software 32