Ground contact lost (ErrorCode 127)
AutoForce
80
kg
80
kg
500 kg
2 9
A B
Working screen - ErrorCode 127
A Number of faulty sensor
B Row number of faulty sensor
No adequate coulter pressure can be built up.
The resistance is too great.
The warning message appears if the measured
force is too low over a certain period. There is
no ground contact. The correct placement depth
of the seed is no longer ensured.
¾ Increase the target value.
¾ Till the soil before sowing.
¾ Check the parallelogram on the drill unit for
free movement.
Error codes
Wire break (ErrorCode 87)
5.0
sim
km/h
180Tg / ha 0kg / ha
Tg 182
VC 9 %
Nom. : 100
%
A B
Working screen - ErrorCode 87
A Number of faulty sensor
B Row number of faulty sensor
The connection between job computer and sen-
sor is interrupted.
¾ Check all cables and plug-and-socket con-
nections between job computer and sensor.
¾ Replace defective components as required.
Short-circuit (ErrorCode 88)
0.0
km/h
90 Tg/ha 0.0 kg/ha
A B
Working screen - ErrorCode 88
A Number of faulty sensor
B Row number of faulty sensor
There is a short-circuit between the sensor and
the job computer.
¾ Check all cables and plug-and-socket con-
nections between job computer and sensor.
¾ Replace defective components as required.
18