EasyManua.ls Logo

horsch AutoForce - Error Codes

horsch AutoForce
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ground contact lost (ErrorCode 127)
AutoForce
80
kg
80
kg
500 kg
2 9
A B
Working screen - ErrorCode 127
A Number of faulty sensor
B Row number of faulty sensor
No adequate coulter pressure can be built up.
The resistance is too great.
The warning message appears if the measured
force is too low over a certain period. There is
no ground contact. The correct placement depth
of the seed is no longer ensured.
¾ Increase the target value.
¾ Till the soil before sowing.
¾ Check the parallelogram on the drill unit for
free movement.
Error codes
Wire break (ErrorCode 87)
5.0
sim
km/h
180Tg / ha 0kg / ha
Tg 182
VC 9 %
Nom. : 100
%
A B
Working screen - ErrorCode 87
A Number of faulty sensor
B Row number of faulty sensor
The connection between job computer and sen-
sor is interrupted.
¾ Check all cables and plug-and-socket con-
nections between job computer and sensor.
¾ Replace defective components as required.
Short-circuit (ErrorCode 88)
0.0
km/h
90 Tg/ha 0.0 kg/ha
A B
Working screen - ErrorCode 88
A Number of faulty sensor
B Row number of faulty sensor
There is a short-circuit between the sensor and
the job computer.
¾ Check all cables and plug-and-socket con-
nections between job computer and sensor.
¾ Replace defective components as required.
18
19