EasyManua.ls Logo

Hotpoint FF175BP - Fault Diagnosis Quick Guide

Hotpoint FF175BP
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FAULT DIAGNOSIS QUICK GUIDE
SYMPTOM CAUSE ACTION
Freezer evaporator and air
If freezer temperature OK then advise
temperature are correct. the customer that the compressor will
start when there
is
a demand for
cooling.
Compressor protection is enabled:-
Compressor protection:
a.
If the appliance
is
accidentally
a.
Allow the compressor to cool and
switched OFF and switched the refrigerant to equalise
in
the
immediately back ON. system.
b.
after a mains power cut,
b.
As
a.
above.
C.
Running continuously,
c1.
Check the position
of
the freezer air
d.
Post defrost cycle, sensor;
c2.
Check refrigerant system for leaks
COMPRESSOR
and/or blockages.
NOT RUNNING
d.
At
the end
of
the defrost cycle the
(Fridge Interior
compressor observes a protection
Light Working)
time delay parameterised
in
the
module, this allows the water to
drain away completely.
Compressor has a humming noise Compressor possibly seized or PTC
before the overload switches faulty.
compressor OFF.
Compressor Start or Run windings Check the resistances of the
faulty. compressor windings.
There are situations
of
cooling
See CONTROL MODULE Parameters
demand
in
which the compressor page 14, Section headed Compressor
remains OFF Operation.
Mains plug fuse blown.
Check fuse rating. If the fuse
is
of the
COMPRESSOR
correct rating and has blown then check
NOT RUNNING
appliance for reasons.
(Fridge Interior
Appliance mains cable faulty.
Check the condition of the appliance
Light Not
mains cable and the connections to the
Working)
compressor terminal block.
Installation fault. Advise customer of installation fault.
CUSTOMER
The evaporator fan circulating the air
in
the freezer compartment may be
COMPLAINING
heard.
OF SOUNDS
Cracking sounds: This
is
where
FROM THE
parts inside the fridge freezer
All the sounds described are quite
FREEZER
expand and contract as they rapidly
normal and mean that the appliance
is
(Sounds
change temperature.
functioning correctly.
different
Gurgling sounds: Refrigerant
compared with
my previous
flowing through the system pipes
fridge freezer)
can produce gurgling, bubbling,
roaring or humming sounds.
continued
...