CONTROL MODULE Parameters
Parameters set
in
the module control the appliance
functions.
The minimum and maximum values for temperature are
preset
in
the module. Sensors monitor temperature and
the values are registered
in
the module. Where the sensor
Parameter Values
values are outside the presets a particular function will
Stored
in
the Module
start or stop.
Where a sensor fails, open or closed, the appliance
Direct the Appliance
operation will be controlled by time. The timed values for
Operations-
this are calculated
in
the module.
Fridge door opening times and compressor run times are
monitored by the module. When the total
of
the door open
and compressor run times are equal to or exceed the
parameter values set
in
the eeprom, a defrost sequence
will be initiated.
COMPRESSOR OPERATION
1.
Compressor protection: the compressor switches on
once a minimum safety time lag has elapsed since the
last power-off, thereby allowing refrigerant gas
pressure to reach a point of equilibrium
in
the
refrigerant circuit.
8 minutes
The same minimum safety time is observed
in
the
Compressor Operation -
event of a mains power interruption (voluntary or
involuntary). This compressor protection strategy
is
observed only after the product has been operating
There
are
situations
of
cooling
continuously for the number
of
hours defined in the
demand
in
which
the
compressor
module memory.
remains
off.
24 hours
These
are
as
follows:
2.
Long periods of activity: if the compressor remains
on
for more than a value set
in
the module memory it
is
switched off, even
in
the presence
of
a cooling
demand.
254 minutes
3.
Pause after defrost: at the end of the defrost cycle the
compressor observes a protection time parameterised
in
the module so that the water formed during defrost
can be completely drained.
10 minutes
continued ..... .
14
VVPL00003242_0014