11
Single-phase Microinverter HMS-1600/1800/2000-4T-NA
4.3 Installation Tools
Besides tools recommended below, other auxiliary tools can also be used on site.
Screwdriver Multimeter
Socket Wrench or Allen wrench Marker pen
Diagonal pliers Steel tap
Wire cutters Cable tie
Wire stripper Torque and adjustable wrench
Utility knife
Safety glove Dust masks
Protective goggles Safety shoes
HMS-1600- 4T-NA HMS-1800-4T-NA HMS-2000-4T-NA
Maximum
over current
protection device
(OCPD)
Maximum number
per 10AWG branch
3@208 V
4@240 V
3@208 V
3@240 V
2@208 V
3@240 V
30 A
4.4 AC Branch Circuit Capacity
Hoymiles HMS-1600-4T-NA/HMS-1800-4T-NA/HMS-2000-4T-NA can be used with 12AWG or 10AWG AC
Trunk Cable and the AC Trunk Connector which are provided by Hoymiles. The number of microinverters on
each 12AWG or 10AWG AC branch shall not exceed the limit as shown below.
Note:
1. The number of microinverters that can be connected to each AC branch is determined by the ampacity (also
known as current-carrying capacity) of the cable.
2. 1-in-1, 2-in-1 and 4-in-1 microinverters can be connected to the same AC branch, as long as the total current
does not exceed the ampacity specied in local regulations.

Other manuals for Hoymiles HMS-2000-4T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hoymiles HMS-2000-4T and is the answer not in the manual?

Hoymiles HMS-2000-4T Specifications

General IconGeneral
Output current8.7 A
Charging voltage230 - 275 V
Operating temperature (T-T)-40 - 65 °C
Weight and Dimensions IconWeight and Dimensions
Depth34.6 mm
Width331 mm
Height218 mm
Weight4700 g