Display
Modes
Operating
Characteristics
Screen
Update
Rate
(typical
at
500
ns/div,
no
measurements,
and
the
trigger
frequency
is
250
kHz)
RealTime
RecordLlength
512
8K
16K
32K
Updates/s
150
100
72
47
Repetitive
Mode
normal
8
averages
128
averages
Updates/s
150
100
100
Graticules
You
can
choose
full
grid,
axes,
frame,
or
no
graticule.
Number
of
Screens
On
the
two-channel
models
you
can
select
either
one
or
two
screens.
On
the
four-channel
models
you
can
select
one,
two,
or
four
screens.
Connect-the-Dots
Provides
a
continuous
display,
connecting
the
sample
points
with
straight
lines.
Connect-the-dots
is
operative
for
modes
in
which
a
single-valued
waveform
can
be
connected,
including
average,
envelope,
single,
and
minimum-persistence
modes.
Connect-the-dots
is
not
available
in
the
variable
or
infinite
persistence
mode.
Time
Base
in
the
Repetitive
Mode
Averaging
You
can
specify
the
number
of
averages
in
powers
of
2,
up
to
2,048.
On
each
acquisition,
1/n
times
the
new
data
is
added
to
(n-1)/m
of
the
previous
value
at
each
time
coordinate.
Averaging
operates
continuously,
except
for
the
HP-IB
digitize
command,
for
which
averaging
terminates
at
the
specified
number
of
averages.
Envelope
Provides
a
display
of
the
running
maximum
and
minimum
voltage
levels
at
each
horizontal
time
position.
Minimum
Persistence
One
waveform
data
value
is
displayed
in
each
horizontal
time
position
of
the
display.
The
waveform
is
updated
as
new
data
is
acquired
for
a
particular
horizontal
time
position.
Variable
Persistence
You
can
vary
from
500
ms
to
10
seconds,
the
time
that
each
data
point
is
retained
on
the
display,
or
display
the
points
indefinitely
using
infinite
persistence.
Time
Base
in
the
Real
Time
Mode
Single
Persistence
One
waveform
data
value
is
displayed
in
each
horizontal
time
position.
The
entire
waveform
is
replaced
with
each
new
acquisition.
Infinite
Persistence
Waveform
data
is
allowed
to
continuously
accumulate
on
the
screen,
and
remains
until
display
is
cleared.
Oversampling
Filter
On
time/division
settings
when
less
than
500
points
are
acquired
across
the
screen,
a
built-in
digital
filter
automatically
reconstructs
the
data.
This
filter
is
a
combination
between
a
(Sin
X)/X
and
a
Gaussian
filter
(also
known
as
interpolation).
Peak
Detect
Displays
the
amplitude
of
pulses
that
have
a
pulse
width
of
1
ns
or
wider
regardless
of
the
time
base
setting.
Peak
detect
works
in
real-time
mode
only
at
sample
rates
<250
MSa/s.