Timeout in seconds for execution of a single command using array vendor adapter. Default: 5
minutes >
<CommandTimeout> 300 </CommandTimeout>
</SanProvider>
NOTE:
After increasing the SRM timeout value, you will need to restart the VMware Site Recovery Manager
service.
Virtual machines do not start at recovery site during the test
failover test.
Causes:
The ESX recovery hosts are not configured with the correct HBA port WWN on the recovery EVA.
Error messages
HP EVA Virtualization Adapter error messages are logged to SRM and HP EVA Virtualization Adapter
log files. Table 1 lists error messages and their meanings.
SRM log
SRM Logs (vmware-dr-X.log (X=0 to 9) is located in:
%ALLUSERSPROFILE%\Application Data\VMware\VMware Site Recovery Manager\Logs
ALLUSERSPROFILE=C:\Documents and Settings\All Users
NOTE:
Logs rollover after reaching 5 MB by default
vmware-dr-index contains the most recent Log File number
EVA log
HP EVA Virtualization Adapter log (hpsrmeva.log) is located in:
<SRM Install Path>\scripts\SAN\HP StorageWorks EVA Virtualization Adapter\
logs
For the <SRM Install Path>, see Installation directory, page 21.
Troubleshooting HP EVA Virtualization Adapter30