Cold Load Read
Type:
Purpose:
Description:
HP 9895A
Disc
Memory Command Set
A-39
Disc read.
The cold
load
read
is a
command
to
read
from unit 0,
cylinder °
at
a specified
head
and
sector
address. This
command
consists of a
seek
to
cylinder ° followed by a
read
operation starting
at
the specified
head
and
sector.
Consecutive sectors are
read
until the
bus
controller
stops
the
read.
Following reception of the
Read
command,
parallel poll is
disabled, the
DSJ cleared
and
the
first status bit checked.
If
first status
is
set,
the
format of the disc
is
determined
and
the first status bit cleared.
If
the unit
can
be
accessed, the
9895A performs a seek
to
cylinder 0,
reads
the
specified
sector into the internal buffer,
then
asserts parallel poll
waiting for the
send
data
secondary. After
the
send
data
secondary
is received, parallel poll
is
disabled
and
the
buf-
fered
sector
is
sent
to
the
bus
controller.
When
the
sector
has
been
sent, the controller
fills
the buffer with the next
sector
from the disc
and
then
sends
it
to
the
bus
controller.
This process is
repeated
until
one
of the terminating condi-
tions occurs:
1.
If the unit
becomes
unavailable
or
a
sector
cannot
be
found
when
the buffer is empty, a
byte
tagged
with
EOI is sent.
2.
If
a CRC
error
or
D bit is
encountered,
the
sector
is
sent
followed by a byte tagged with
an
EOI.
3.
If
at
any time during
the
operation
the
device notices
that
it has
been
untalked
or
that
the
bus
controller
has
sent
a byte,
the
transfer
will
be
stopped.
FollOWing
any
of
the
above
terminations,
status
is
updated
and
parallel poll response is re-enabled.
If
there
was
an
error
in reading
data
from
the
disc, the target
address
is
left
pointing
to
the
sector
in which the
error
occurred. Other-
wise, the target
sector
points to the
sector
following the last
sector
read
from
the
disc.
The cold load
read
uses unbuffered HP-IB protocol, al-
though
all
sector
transfers take place
through
the buffer.
Thus, there is a
pause
in
data
flow to the HP-IB
each
time
the buffer is re-filled from
the
disc. This
pause
occurs
at
the
beginning of the
read
and
after every
sector
is transferred.
Depending
on
when
the
read
is started
and
the
staggering
of the sectors (see the
Format
command),
this inter-sector
pause
may
be
up
to
160
milliseconds long.

Table of Contents

Other manuals for HP 9845B/C CE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 9845B/C CE and is the answer not in the manual?

HP 9845B/C CE Specifications

General IconGeneral
BrandHP
Model9845B/C CE
CategoryStorage
LanguageEnglish

Related product manuals