EasyManuals Logo
Home>HP>Server>AlphaServer ES80

HP AlphaServer ES80 Upgrade Manual

HP AlphaServer ES80
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
Restore power to the system. You will receive a series of error messages. This is to be
expected, since the console is identifying components not yet configured into the system
network.
1. After you return power, the system will begin its software power-up. The Server
Management will discover any newly added drawers and report them to you.
X
2. Server management tells you what command to run to include this newly discovered
drawer.
Y
3. The system will continue to power up. All during its power-up sequence it will continue
to broadcast the information shown at
X and Y until you provide manual intervention to
include it in the group.
4. In this 4P example, server management has succeeded in forming a stable group with the
included components.
[ But you can see at \ that the system is only including one 2P
drawer, not your second 2P drawer, ID#1.
5. At
], you can see that the system is still broadcasting the hardware issue and your
intervention instructions.
6. Enter the command
set membership –add –ca 0 –dr 1 MBM. ^
If you have added 2 or three 2P drawers, server management will be broadcasting the
commands you need to enter to include these additional drawers as well.
Table 4–1 Set Membership Commands
Upgrading to Dwr ID Command
4P 1
set membership –add –ca 0 –dr 1
Configure and Troubleshoot 4-3

Table of Contents

Other manuals for HP AlphaServer ES80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP AlphaServer ES80 and is the answer not in the manual?

HP AlphaServer ES80 Specifications

General IconGeneral
BrandHP
ModelAlphaServer ES80
CategoryServer
LanguageEnglish

Related product manuals