Front status LEDs: Includes:
4x power supply status LEDs
10x line card status LEDs
2x management module status LEDs
4x line module port state LEDs (includes one LED to indicate port speed, one user LED to indicate line
module port fault and two reserved LEDs).
Rear status LEDs: Includes:
3x fan tray status LEDs
3x fan status LEDs (indicate status of the six fans in each fan tray).
Power supply units (PSUs) and slots
The Aruba 6400 has four power supply unit slots that support the R0X35A Aruba 6400 1800W Power Supply
and the R0X36A Aruba 6400 3000W Power Supply.
Figure 10: Aruba 6400 3000W Power Supply (R0X36A)
2
3
1
4
1 Power LED (green)
2 Power fail LED (amber)
3 Power supply handle
4 Latch release tab
A single PSU is sucient for fans and management cards to come up and provide user access and
diagnostics.
At 220 V AC, only two PSUs are required for full operation and a single PSU is sucient for the fans and
management cards to come up and provide user access/diagnostics.
At 220 V AC: Installing three PSUs oers 2+1 redundancy and installing all four PSUs oers 2+2
redundancy.
At 110 V AC: The switch oers N + 1 redundancy.
The PSUs are hot-swappable. The chassis can be connected to an AC power source for a given PSU slot
while the PSU for that slot is being removed or installed.
PSU LEDs
There are two LEDs on a PSU to indicate PSU status:
Power LED (green)
Power fail LED (amber)