Component identification 72
FBWC module LED definitions
P222 and P430 modules
The FBWC module has three LEDs (one amber and two green). The LEDs are duplicated on the reverse
side of the FBWC module to facilitate status viewing.
1 - Amber 2 - Green 3 - Green Interpretation
The FBWC module is not powered.
Off
The FBWC microcontroller is executing from within its
boot loader and receiving new flash code from the host
controller.
Off
The FBWC module is powering up, and the capacitor
pack is charging.
Off
The FBWC module is idle, and the capacitor pack is
charging.
Off
The FBWC module is idle, and the capacitor pack is
charged.
Off
The FBWC module is idle, the capacitor pack is
charged, and the cache contains data that has not yet
been written to the drives.
The current backup is complete with no errors.
The current backup failed, and data has been lost.
Flashing 1 Hz
A power error occurred during the previous or current
boot. Data might be corrupt.
An overtemperature condition exists.
The capacitor pack is not attached.
Flashing 2 Hz
The capacitor has been charging for 10 minutes, but
has not reached sufficient charge to perform a full
backup.
On
The current backup is complete, but power
fluctuations occurred during the backup.
The cache module microcontroller has failed.