Specifications 86
BTUs per hour
2013 at 115 V AC input
2004 at 200 V AC input
1941 at 230 V AC input
Power supply output
Rated steady-state power
460 W at 100 V to 120 V AC input
460 W at 200 V to 240 V AC input
Maximum peak power
460 W at 100 V to 120 V AC input
460 W at 200 V to 240 V AC input
HPE ProLiant 460 W CS power supply (94% efficiency)
Specification Value
Rated input power
495 W at 230V AC input
Btus per hour
1736 at 115V AC input
1694 at 200V AC input
1687 at 230V AC input
Rated steady-state power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
Maximum peak power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
HPE ProLiant 750 W CS hot-plug power supply (94% efficiency)
Specification Value
Input requirements
Rated input voltage
Maximum rated input power
808 W at 230 V AC input
Btus per hour
2834 at 115 V AC input
2769 at 200 V AC input
2758 at 230 V AC input
Power supply output
Rated steady-state power
750 W at 100 V to 120 V AC input
750 W at 200 V to 240 V AC input
Maximum peak power
750 W at 100 V to 120 V AC input
750 W at 200 V to 240 V AC input
Hot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical and heat loading for the
server, see the Hewlett Packard Enterprise Power Advisor website
(http://www.hpe.com/info/rackandpower).