AlarmEvent exampleTree viewFirmware state
HPE SimpliVity 380 SSD Array
Warning
Physical drive at slot:9 is
missing.
Drive Set 0 in the SSD Array
can tolerate the loss of 1 more
drive(s) before the HPE Om-
niStack host fails.
MissingMissing
HPE SimpliVity 380 Physical
Drive Health State Error
Physical drive S0SDNE-
ABC01153 at slot:0 health
state has changed from
Healthy to Offline.
OfflineOffline
HPE SimpliVity 380 SSD Array
Critical
Drive Set 0 in the SSD Array
can tolerate the loss of 0 more
drive(s) before the HPE Om-
niStack host fails.
HPE SimpliVity 380 Physical
Drive Predictive Failure
Physical drive S0SDNE-
ABC01131 at slot:1 has expe-
rienced a high number of pre-
dictive failures. Replace it as
soon as possible.
HealthyPredictiveFailure
HPE SimpliVity 380 SSD Array
- Rebuilding the maximum
number of drives
Physical drive S0SDNE-
ABC01153 at slot:0 health
state has changed from Offline
to Rebuilding.
Rebuilding (with a percent
complete)
Rebuild
HPE SimpliVity 380 SSD Array
Critical
The SSD array currently has 1
drive(s) rebuilding.
HPE SimpliVity 380 Physical
Drive Health State Error
Physical drive S0SDNE-
ABC01131 at slot:1 health
state has changed from
Healthy to Failed.
FailedUnconfigured, bad
HPE SimpliVity 380 SSD Array
Critical
Drive Set 0 in the SSD Array
can tolerate the loss of 0 more
drive(s) before the HPE Om-
niStack host fails.
HPE SimpliVity 380 Physical
Drive Health State Error
Physical drive S0SDNE-
ABC01131 at slot:1 has a for-
eign configuration.
UnconfiguredUnconfigured, good
HPE SimpliVity 380 Physical
Drive Foreign Configuration
Physical drive S0SDNE-
ABC01131 at slot:1 health
state has changed from
Healthy to Unconfigured.
HPE SimpliVity 380 SSD Array
Critical
Drive Set 0 in the SSD Array
can tolerate the loss of 0 more
drive(s) before the HPE Om-
niStack host fails.
Server troubleshooting 24