AlarmEvent exampleTree viewFirmware state
HPE SimpliVity 380 SSD Array
Warning
Physical drive at slot:9 is
missing.
Drive Set 0 in the SSD Array
can tolerate the loss of 1 more
drive(s) before the HPE Om-
niStack host fails.
MissingMissing
HPE SimpliVity 380 Physical
Drive Health State Error
Physical drive S0SDNE-
ABC01153 at slot:0 health
state has changed from
Healthy to Offline.
OfflineOffline
HPE SimpliVity 380 SSD Array
Critical
Drive Set 0 in the SSD Array
can tolerate the loss of 0 more
drive(s) before the HPE Om-
niStack host fails.
HPE SimpliVity 380 Physical
Drive Predictive Failure
Physical drive S0SDNE-
ABC01131 at slot:1 has expe-
rienced a high number of pre-
dictive failures. Replace it as
soon as possible.
HealthyPredictiveFailure
HPE SimpliVity 380 SSD Array
- Rebuilding the maximum
number of drives
Physical drive S0SDNE-
ABC01153 at slot:0 health
state has changed from Offline
to Rebuilding.
Rebuilding (with a percent
complete)
Rebuild
HPE SimpliVity 380 SSD Array
Critical
The SSD array currently has 1
drive(s) rebuilding.
HPE SimpliVity 380 Physical
Drive Health State Error
Physical drive S0SDNE-
ABC01131 at slot:1 health
state has changed from
Healthy to Failed.
FailedUnconfigured, bad
HPE SimpliVity 380 SSD Array
Critical
Drive Set 0 in the SSD Array
can tolerate the loss of 0 more
drive(s) before the HPE Om-
niStack host fails.
HPE SimpliVity 380 Physical
Drive Health State Error
Physical drive S0SDNE-
ABC01131 at slot:1 has a for-
eign configuration.
UnconfiguredUnconfigured, good
HPE SimpliVity 380 Physical
Drive Foreign Configuration
Physical drive S0SDNE-
ABC01131 at slot:1 health
state has changed from
Healthy to Unconfigured.
HPE SimpliVity 380 SSD Array
Critical
Drive Set 0 in the SSD Array
can tolerate the loss of 0 more
drive(s) before the HPE Om-
niStack host fails.
Server troubleshooting 24
Documentation Feedback: doc-feedback-hpe-storage@hpe.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP HPE SimpliVity 380 Gen10 and is the answer not in the manual?

HP HPE SimpliVity 380 Gen10 Specifications

General IconGeneral
ProcessorIntel Xeon Scalable processors
Hypervisor SupportVMware vSphere, Microsoft Hyper-V
Network10GbE
Form Factor2U
Power SupplyRedundant Power Supplies
Operating SystemWindows Server
ManagementHPE OneView
MemoryUp to 6 TB DDR4 ECC Registered DIMMs