HP L1940
D-SUB signal connector
DVI signal connector
Power cord socket
Upstream Port
Two downstream ports
5.2 Unit dimension / Weight
Set dimension (incl. pedestal): 413(W) * 477(H) * 265(D) mm
Net weight. : 8.4 kg
5.3 Tilt and swivel base
Basic base:
tilt angle : -5 ° to +35 ° ( operation )
swivel rotation : ± 90°
5.4 Transportation packages
5.4.1 Shipping dimension/Weight
Carton dimension. : 524(W) * 239(D) * 513(H) mm
Gross weight. : 10 Kg
5.4.2 Block unit / Palletization
It use two kind of pallets, which mixed into container (please sheet sheet 560)
A type pallet:
layers / block
sets/layer sets/block unit
41040
blocks/container
20 feet 40 feet
920
6.0 Environmental characteristics
6.1 Susceptibility of display to external environment
6.1.1 Temperature Ranges
Operating Temperature (Independent of altitude) : 5 C to 35 C.
Non-Operating Temperature (Independent of altitude) : -20 C to 60 C.
6.1.2 Humidity
Operating (non-condensing) : 20% to 80%
Non-Operating (38.7 C maximum wet bulb temperature) : 5% to 90%
6.1.3 Altitude
Operating 0 to 12,000 feet [3,658 m]. Equivalent to 14.7 to 10.1 psia.
Non-Operating 0 to 40,000 feet [12,192 m]. Equivalent to 14.7 to 4.4 psia
o
o
o
o
o
GENERAL PRODUCT SPECIFICATION(Continued)
18
BRAND : HP L1940
19 inch LCD Monitor
TYPE : EJ6B50/02
8639 000 15804
2004-08-31
2004-08-31
590
28
Jacky Lee