Other Wiring Rules:
All twisted-pair wires used for 10 Mbps, and 100 Mbps operation must be
twisted through the entire length of the cable. The wiring sequence must
conform to EIA/TIA 568-B (not USOC). See “Twisted-Pair Cable Pin
Assignments” later in this appendix for a listing of the signals used on each
pin.
For 1000Base-T connections, all four pairs of wires in the cable must be
available for data transmission. See “Note on 1000Base-T Cable Require-
ments” on page B-2 for more information on 1000Base-T cabling.
For 10 Mbps connections to the ports, you can use Category 3, 4, or 5
unshielded twisted-pair cable, as supported by the IEEE 802.3 Type
10Base-T standard.
For 100 Mbps connections to the ports, use 100-ohm Category 5 UTP or
STP cable only, as supported by the IEEE 802.3u Type 100Base-TX
standard.
For 1000 Mbps connections, 100-ohm Category 5e or better cabling is
recommended.
To provide Power over Ethernet to the access point, all 4 pairs must be
connected for any network cable attached to this port; the cable must
meet ISO/DIS 11801 Class D requirements and IEEE 802.3af requirements.

Table of Contents

Other manuals for HP ProCurve 2610

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2610 and is the answer not in the manual?

HP ProCurve 2610 Specifications

General IconGeneral
BrandHP
ModelProCurve 2610
CategorySwitch
LanguageEnglish

Related product manuals