Software Fixes in Release L.10.01 - L.11.09
Release L.10.23
Release L.10.23
Versions L.10.21 and L.10.22 were never released.
Problems Resolved in Release L.10.23 (not a general release)
Enhancement — Support for the following products was added: J8768A, J9030A, J9033A,
and J9064A
Release L.10.24
Problems Resolved in Release L.10.24
CLI (PR_1000332352) — The output of a show int brief command should show the
negotiated flow control status rather than the flow control configuration setting.
CLI (PR_1000390970) — The command tftp-enable is removed from the CLI since that
functionality is served by tftp server|client.
CLI/config (PR_1000391119) — Copying a configuration file to a switch with a BPDU
protection timeout value set may produce an error similar to:
CCCCCline: 10007. 1200: Error setting configuration.
CLI/Show tech (PR_1000378957) — After a hotswap of chassis modules, the show tech
statistics value for the field “linked port on box” may be inaccurate.
CLI (PR_1000240838) — If an invalid time is entered using clock set command, the switch
responds with an “invalid date” error.
CLI (PR_1000199785)The tab help function (command-completion) for “IP RIP authen-
tication” is inaccurate. The help selection lists “OCTET-STR Set authentication key” when it
should be “ASCII-STR Set RIP auhentication key (maximum 16 characters)".
CLI (PR_1000373443) — The CLI update command help text and confirmation message is
misleading and confusing.
Crash (PR_1000392863) Switch may crash when setmib tcpConnState is used, with a
message similar to:
NMI event SW:IP=0x0079f4a0 MSR:0x00029210 LR:0x006dca60
Task='eTelnetd' Task ID=0x8a7cbb0 cr: 0x20000042 sp:0x08a7c871
Daylight savings (PR_1000364740) — Due to the passage of the Energy Policy Act of
2005, Pub. L. no. 109-58, 119 Stat 594 (2005), starting in March 2007 daylight time in the United
States will begin on the second Sunday in March and end on the first Sunday in November.
Enhancement (PR_1000373226) — Support was added for a future SFP transceiver.
Enhancement (PR_1000335860) — This enhancement provides a configuration option
for the source IP address field of SNMP response and generated trap PDUs.

Table of Contents

Other manuals for HP ProCurve J8766A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve J8766A and is the answer not in the manual?

HP ProCurve J8766A Specifications

General IconGeneral
BrandHP
ModelProCurve J8766A
CategorySoftware
LanguageEnglish

Related product manuals