114
Software Fixes in Release L.10.01 - L.11.09
Release L.10.25
■ Enhancement (PR_1000379804) — Historical information about MAC addresses that
have been moved has been added to the show tech command output.
■ Enhancement (PR_1000385565) — Port security static mac address limit increased to 32.
■ LED (PR_1000378980) — The full-duplex (FDx) mode LED incorrectly illuminates when
ports on J8765B module negotiate to half-duplex.
■ MDIX (PR_1000378954) — Inaccurate detection of MDIX/MDI mode on J8768A and
J9033A modules.
■ Syslog (PR_1000379802) — Forwarding of event log message to a configured syslog server
is not disabled when a specific event log message has been disabled via MIB.
■ Trunking (PR_1000238829) — Trunks numbered trk10 and greater cause the output from
the CLI command show span output to be misaligned.
■ Web UI (PR_1000326265) — Attempting to access the Web UI of a stack member hangs
the browser.
Release L.10.25
Problems Resolved in Release L.10.25 (never released)
■ BPDU Protection (PR_1000395569) — BPDU-protection fails after module hot-swap.
■ CLI/Counters (PR_1000379222) — Jumbo sized frames received decrement "Total Rx
Errors" counters. 32 bit counter rolls from 0 backwards to 4,294,967,295 and continues to
decrement with each received Jumbo frame.
■ CLI (PR_1000380660) — The show tech transceivers CLI command displays the wrong
message when inserting an "A" version transceiver into a switch that only supports "B"
version transceivers. Also, "B" version CX4 transceivers show up as "A" and "A" version SR,
LR, and ER transceivers show up as "B" versions.
■ Enhancement (PR_1000376626) — Enhanced CLI qos dscp-map help help and show dscp-
map text to warn user that inbound classification based on DSCP codepoints only occurs if
qos type-of-service diff-services is also configured.
■ Menu (PR_1000392862) — The menu will allow invalid values (greater than 720 sec) to
be entered for the SNTP poll interval.
■ Module hot-swap (PR_1000412501) — Some modules fail to initialize following hotswap,
but have no trouble initializing with warm or cold boot.
■ Traceroute (PR_1000379199) — The reported "traceroute" time is inaccurate; it is one
decimal place off.