Software Fixes in Release L.10.01 - L.11.09
Release L.10.25
Enhancement (PR_1000379804) — Historical information about MAC addresses that
have been moved has been added to the show tech command output.
Enhancement (PR_1000385565) — Port security static mac address limit increased to 32.
LED (PR_1000378980) — The full-duplex (FDx) mode LED incorrectly illuminates when
ports on J8765B module negotiate to half-duplex.
MDIX (PR_1000378954) — Inaccurate detection of MDIX/MDI mode on J8768A and
J9033A modules.
Syslog (PR_1000379802) — Forwarding of event log message to a configured syslog server
is not disabled when a specific event log message has been disabled via MIB.
Trunking (PR_1000238829) — Trunks numbered trk10 and greater cause the output from
the CLI command show span output to be misaligned.
Web UI (PR_1000326265) — Attempting to access the Web UI of a stack member hangs
the browser.
Release L.10.25
Problems Resolved in Release L.10.25 (never released)
BPDU Protection (PR_1000395569) — BPDU-protection fails after module hot-swap.
CLI/Counters (PR_1000379222) — Jumbo sized frames received decrement "Total Rx
Errors" counters. 32 bit counter rolls from 0 backwards to 4,294,967,295 and continues to
decrement with each received Jumbo frame.
CLI (PR_1000380660) — The show tech transceivers CLI command displays the wrong
message when inserting an "A" version transceiver into a switch that only supports "B"
version transceivers. Also, "B" version CX4 transceivers show up as "A" and "A" version SR,
LR, and ER transceivers show up as "B" versions.
Enhancement (PR_1000376626) — Enhanced CLI qos dscp-map help help and show dscp-
map text to warn user that inbound classification based on DSCP codepoints only occurs if
qos type-of-service diff-services is also configured.
Menu (PR_1000392862) — The menu will allow invalid values (greater than 720 sec) to
be entered for the SNTP poll interval.
Module hot-swap (PR_1000412501) — Some modules fail to initialize following hotswap,
but have no trouble initializing with warm or cold boot.
Traceroute (PR_1000379199) — The reported "traceroute" time is inaccurate; it is one
decimal place off.

Table of Contents

Other manuals for HP ProCurve J8766A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve J8766A and is the answer not in the manual?

HP ProCurve J8766A Specifications

General IconGeneral
BrandHP
ModelProCurve J8766A
CategorySoftware
LanguageEnglish

Related product manuals